Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Human liver lipids: representativity of determinations on material obtained by fine-needle aspiration biopsy

Wiebe, Thomas LU and Belfrage, Per LU (1971) In Scandinavian Journal of Clinical & Laboratory Investigation 28(4). p.453-457
Abstract
Triglycerides and phospholipids in human liver material obtained by fine-needle aspiration biopsy have been determined according to an improved version of a previously developed method. The molar ratios of these lipids have been compared with the same ratios determined on material representing whole liver. The average value of the ratios in the fine-needle specimens was 101% (83-113%) of the corresponding whole-liver value. The variation coefficient of determinations on several fine-needle specimens from the same liver was 10% (4-17%). The least difference, between the ratiosof two consecutive fine-needle specimens, to ensure a significant difference was 30%.
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Aspiration, biopsy, human, liver, ratio TG/PL, representativity
in
Scandinavian Journal of Clinical & Laboratory Investigation
volume
28
issue
4
pages
453 - 457
publisher
Informa Healthcare
external identifiers
  • pmid:5157046
  • scopus:0015178843
ISSN
1502-7686
DOI
10.3109/00365517109095723
language
English
LU publication?
yes
id
55ce7790-f13c-437d-9523-bee93f5cb544 (old id 1102555)
date added to LUP
2016-04-01 16:03:15
date last changed
2021-01-03 04:42:45
@article{55ce7790-f13c-437d-9523-bee93f5cb544,
  abstract     = {{Triglycerides and phospholipids in human liver material obtained by fine-needle aspiration biopsy have been determined according to an improved version of a previously developed method. The molar ratios of these lipids have been compared with the same ratios determined on material representing whole liver. The average value of the ratios in the fine-needle specimens was 101% (83-113%) of the corresponding whole-liver value. The variation coefficient of determinations on several fine-needle specimens from the same liver was 10% (4-17%). The least difference, between the ratiosof two consecutive fine-needle specimens, to ensure a significant difference was 30%.}},
  author       = {{Wiebe, Thomas and Belfrage, Per}},
  issn         = {{1502-7686}},
  keywords     = {{Aspiration; biopsy; human; liver; ratio TG/PL; representativity}},
  language     = {{eng}},
  number       = {{4}},
  pages        = {{453--457}},
  publisher    = {{Informa Healthcare}},
  series       = {{Scandinavian Journal of Clinical & Laboratory Investigation}},
  title        = {{Human liver lipids: representativity of determinations on material obtained by fine-needle aspiration biopsy}},
  url          = {{http://dx.doi.org/10.3109/00365517109095723}},
  doi          = {{10.3109/00365517109095723}},
  volume       = {{28}},
  year         = {{1971}},
}