Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Determination of cotinine in urine using glass capillary gas chromatography and selective detection, with special reference to the biological monitoring of passive smoking

Skarping, Gunnar LU ; Willers, Stefan LU and Dalene, Marianne LU (1988) In Journal of Chromatography A 454. p.293-301
Abstract
A capillary gas chromatographic (GC) method using selected-ion monitoring (SIM) was developed for the analysis of cotinine (C.A.S. No. 486-56-6) in human urine. The method is based on basic extraction of cotinine from 2 ml of urine into dichloromethane. After evaporation of the dichloromethane solution to dryness, 100 microliters of toluene were added, prior to GC-mass spectrometric (MS) analysis. Trideuterated cotinine (C.A.S. No. 97664-65-8) was used as the internal standard. More than 1000 automatic chromatographic analyses were made without column degradation. Molecular ions (M) of cotinine and trideuterated cotinine, (m/e = 176 and 179), were monitored in the electron impact (EI) mode and m/e = 177 (M + 1) and m/e = 180 (M + 1) in the... (More)
A capillary gas chromatographic (GC) method using selected-ion monitoring (SIM) was developed for the analysis of cotinine (C.A.S. No. 486-56-6) in human urine. The method is based on basic extraction of cotinine from 2 ml of urine into dichloromethane. After evaporation of the dichloromethane solution to dryness, 100 microliters of toluene were added, prior to GC-mass spectrometric (MS) analysis. Trideuterated cotinine (C.A.S. No. 97664-65-8) was used as the internal standard. More than 1000 automatic chromatographic analyses were made without column degradation. Molecular ions (M) of cotinine and trideuterated cotinine, (m/e = 176 and 179), were monitored in the electron impact (EI) mode and m/e = 177 (M + 1) and m/e = 180 (M + 1) in the chemical ionization (CI) mode with isobutane. The correlation coefficient with SIM and EI was 0.998 (5-20 ng/ml) and with CI was (0.2-2 ng/ml). For thermionic specific detection the correlation coefficient was 0.998 (10-510 ng/ml). Only capillary columns with an apolar bonded stationary phase film thickness of 1 micron showed sufficient inertness for cotinine analysis at the sub ng/ml level. The relative standard deviations for 5 and 20 ng/ml were 5.2 and 3.5% respectively (n = 12) using EI. Spiked urine samples from six non-smokers (5 ng/ml) showed a relative standard deviation of 5%. The overall recovery (25 ng/ml) was 100 +/- 4%. The minimum detectable concentration, using SIM, was ca. 2 ng/ml in the EI mode and ca. 0.2 ng/ml in the CI mode. The half-time for cotinine was ca. 18 h for both active smokers and non-smokers. (Less)
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Chromatography A
volume
454
pages
293 - 301
publisher
Elsevier
external identifiers
  • pmid:3235599
  • scopus:0023737921
ISSN
0021-9673
language
English
LU publication?
yes
id
a64a468c-25ba-444d-820b-289678bc6b9e (old id 1104331)
date added to LUP
2016-04-01 16:00:54
date last changed
2021-01-03 09:58:54
@article{a64a468c-25ba-444d-820b-289678bc6b9e,
  abstract     = {{A capillary gas chromatographic (GC) method using selected-ion monitoring (SIM) was developed for the analysis of cotinine (C.A.S. No. 486-56-6) in human urine. The method is based on basic extraction of cotinine from 2 ml of urine into dichloromethane. After evaporation of the dichloromethane solution to dryness, 100 microliters of toluene were added, prior to GC-mass spectrometric (MS) analysis. Trideuterated cotinine (C.A.S. No. 97664-65-8) was used as the internal standard. More than 1000 automatic chromatographic analyses were made without column degradation. Molecular ions (M) of cotinine and trideuterated cotinine, (m/e = 176 and 179), were monitored in the electron impact (EI) mode and m/e = 177 (M + 1) and m/e = 180 (M + 1) in the chemical ionization (CI) mode with isobutane. The correlation coefficient with SIM and EI was 0.998 (5-20 ng/ml) and with CI was (0.2-2 ng/ml). For thermionic specific detection the correlation coefficient was 0.998 (10-510 ng/ml). Only capillary columns with an apolar bonded stationary phase film thickness of 1 micron showed sufficient inertness for cotinine analysis at the sub ng/ml level. The relative standard deviations for 5 and 20 ng/ml were 5.2 and 3.5% respectively (n = 12) using EI. Spiked urine samples from six non-smokers (5 ng/ml) showed a relative standard deviation of 5%. The overall recovery (25 ng/ml) was 100 +/- 4%. The minimum detectable concentration, using SIM, was ca. 2 ng/ml in the EI mode and ca. 0.2 ng/ml in the CI mode. The half-time for cotinine was ca. 18 h for both active smokers and non-smokers.}},
  author       = {{Skarping, Gunnar and Willers, Stefan and Dalene, Marianne}},
  issn         = {{0021-9673}},
  language     = {{eng}},
  pages        = {{293--301}},
  publisher    = {{Elsevier}},
  series       = {{Journal of Chromatography A}},
  title        = {{Determination of cotinine in urine using glass capillary gas chromatography and selective detection, with special reference to the biological monitoring of passive smoking}},
  volume       = {{454}},
  year         = {{1988}},
}