Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Nanospray mass spectrometry with indirect conductive graphite coating

Viberg, Peter LU ; Nilsson, Staffan LU and Skog, Kerstin LU (2004) In Analytical Chemistry 76(14). p.4241-4244
Abstract
An easy and cost-effective method to manufacture a robust conductive graphite coating for nanospray mass spectrometry (nESI-MS) and capillary electrophoresis (CE)-nESI-MS is described. The method involves graphite coating of a tube sleeve, into which the nESI emitter is inserted and connected to a transfer capillary, instead of coating the actual emitter. The coating, made of graphite from a pencil and epoxy glue, was stable over long periods of use (>80 h) and showed excellent resistance toward various solvents. Stable electrospray was achieved in the investigated flow range (150-900 nL min(-1)), and salbutamol, diphenhydramine, and nortriptyline (M-w: 239-263 g mol(-1)) were detected in the nanomole per liter range during continuous... (More)
An easy and cost-effective method to manufacture a robust conductive graphite coating for nanospray mass spectrometry (nESI-MS) and capillary electrophoresis (CE)-nESI-MS is described. The method involves graphite coating of a tube sleeve, into which the nESI emitter is inserted and connected to a transfer capillary, instead of coating the actual emitter. The coating, made of graphite from a pencil and epoxy glue, was stable over long periods of use (>80 h) and showed excellent resistance toward various solvents. Stable electrospray was achieved in the investigated flow range (150-900 nL min(-1)), and salbutamol, diphenhydramine, and nortriptyline (M-w: 239-263 g mol(-1)) were detected in the nanomole per liter range during continuous pumping. CE-nESI-MS analysis gave excellent signal-to-noise ratios for 100-fmol injections. The technique allows simple exchange of the nESI emitter to suit a specific flow rate, and it minimizes risk of corona discharge. (Less)
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Analytical Chemistry
volume
76
issue
14
pages
4241 - 4244
publisher
The American Chemical Society (ACS)
external identifiers
  • wos:000222706400052
  • pmid:15253670
  • scopus:3242676968
  • pmid:15253670
ISSN
1520-6882
DOI
10.1021/ac049728e
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004), Applied Nutrition and Food Chemistry (011001300)
id
89c9ece1-7ea2-4d87-981c-5b00a7ffa238 (old id 138612)
date added to LUP
2016-04-01 12:12:38
date last changed
2023-09-01 23:21:54
@article{89c9ece1-7ea2-4d87-981c-5b00a7ffa238,
  abstract     = {{An easy and cost-effective method to manufacture a robust conductive graphite coating for nanospray mass spectrometry (nESI-MS) and capillary electrophoresis (CE)-nESI-MS is described. The method involves graphite coating of a tube sleeve, into which the nESI emitter is inserted and connected to a transfer capillary, instead of coating the actual emitter. The coating, made of graphite from a pencil and epoxy glue, was stable over long periods of use (>80 h) and showed excellent resistance toward various solvents. Stable electrospray was achieved in the investigated flow range (150-900 nL min(-1)), and salbutamol, diphenhydramine, and nortriptyline (M-w: 239-263 g mol(-1)) were detected in the nanomole per liter range during continuous pumping. CE-nESI-MS analysis gave excellent signal-to-noise ratios for 100-fmol injections. The technique allows simple exchange of the nESI emitter to suit a specific flow rate, and it minimizes risk of corona discharge.}},
  author       = {{Viberg, Peter and Nilsson, Staffan and Skog, Kerstin}},
  issn         = {{1520-6882}},
  language     = {{eng}},
  number       = {{14}},
  pages        = {{4241--4244}},
  publisher    = {{The American Chemical Society (ACS)}},
  series       = {{Analytical Chemistry}},
  title        = {{Nanospray mass spectrometry with indirect conductive graphite coating}},
  url          = {{http://dx.doi.org/10.1021/ac049728e}},
  doi          = {{10.1021/ac049728e}},
  volume       = {{76}},
  year         = {{2004}},
}