Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.

Knutsson, Linda LU orcid ; Ståhlberg, Freddy LU and Wirestam, Ronnie LU orcid (2010) In Magma 23. p.1-21
Abstract
Absolute quantification of cerebral blood flow, cerebral blood volume and mean transit time is desirable in the determination of tissue viability thresholds and tissue at risk in acute ischaemic stroke, as well as in cases where a global reduction in cerebral blood flow is expected, for example, in patients with dementia or depressive disorders. Absolute values are also useful when comparing sequential examinations of tissue perfusion parameters, for example, in the monitoring and follow-up of various kinds of therapy. Regardless of the method employed, a number of assumptions and approximations must be made to obtain absolute measures of perfusion. Furthermore, the different stages of data acquisition and processing are associated with... (More)
Absolute quantification of cerebral blood flow, cerebral blood volume and mean transit time is desirable in the determination of tissue viability thresholds and tissue at risk in acute ischaemic stroke, as well as in cases where a global reduction in cerebral blood flow is expected, for example, in patients with dementia or depressive disorders. Absolute values are also useful when comparing sequential examinations of tissue perfusion parameters, for example, in the monitoring and follow-up of various kinds of therapy. Regardless of the method employed, a number of assumptions and approximations must be made to obtain absolute measures of perfusion. Furthermore, the different stages of data acquisition and processing are associated with various degrees of uncertainty. In this review, the problems of particular relevance to absolute quantification of cerebral perfusion parameters using dynamic susceptibility contrast magnetic resonance imaging are discussed, and possible solutions are outlined. (Less)
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Magma
volume
23
pages
1 - 21
publisher
Springer
external identifiers
  • wos:000274299500001
  • pmid:19960361
  • scopus:76649106726
ISSN
1352-8661
DOI
10.1007/s10334-009-0190-2
project
Optimisation and Validation of Dynamic Susceptibility Contrast MRI
language
English
LU publication?
yes
id
cd0b19c7-ceba-4544-87e8-4d54d55b5c08 (old id 1524000)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/19960361?dopt=Abstract
date added to LUP
2016-04-04 13:51:14
date last changed
2022-04-13 12:04:44
@article{cd0b19c7-ceba-4544-87e8-4d54d55b5c08,
  abstract     = {{Absolute quantification of cerebral blood flow, cerebral blood volume and mean transit time is desirable in the determination of tissue viability thresholds and tissue at risk in acute ischaemic stroke, as well as in cases where a global reduction in cerebral blood flow is expected, for example, in patients with dementia or depressive disorders. Absolute values are also useful when comparing sequential examinations of tissue perfusion parameters, for example, in the monitoring and follow-up of various kinds of therapy. Regardless of the method employed, a number of assumptions and approximations must be made to obtain absolute measures of perfusion. Furthermore, the different stages of data acquisition and processing are associated with various degrees of uncertainty. In this review, the problems of particular relevance to absolute quantification of cerebral perfusion parameters using dynamic susceptibility contrast magnetic resonance imaging are discussed, and possible solutions are outlined.}},
  author       = {{Knutsson, Linda and Ståhlberg, Freddy and Wirestam, Ronnie}},
  issn         = {{1352-8661}},
  language     = {{eng}},
  pages        = {{1--21}},
  publisher    = {{Springer}},
  series       = {{Magma}},
  title        = {{Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.}},
  url          = {{http://dx.doi.org/10.1007/s10334-009-0190-2}},
  doi          = {{10.1007/s10334-009-0190-2}},
  volume       = {{23}},
  year         = {{2010}},
}