Microbial biosensor for the analysis of 2,4-dichlorophenol
(2005) In Analytical Letters 38(7). p.1071-1083- Abstract
- A flow injection cell-based biosensor was constructed for 2,4-dichlorophenol (DCP) analysis by using a Clark-type oxygen electrode as a transducer. A mixed bacterial culture capable to biodegrade DCP was immobilized between a Teflon membrane and a dialysis membrane and attached to the oxygen electrode. Optimization of the flow rate, the injection volume, the carrier buffer concentration, and pH was carried out. Under optimum conditions (100 mM phosphate buffer, pH 7.50; flow rate 0.10 mL min(-1); sample volume 100 mL), the sensor response was linear between 0.01 and 0.30 mM DCP. The detection limit was 0.02 mM DCP, and the sensor was quite stable during 5 days of operation.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/155160
- author
- Jantra, Jongjit LU ; Zilouei, Hamid LU ; Liu, Jing LU ; Guieysse, Benoit LU ; Thavarungkul, P ; Kanatharana, P and Mattiasson, Bo LU
- organization
- publishing date
- 2005
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Analytical Letters
- volume
- 38
- issue
- 7
- pages
- 1071 - 1083
- publisher
- Taylor & Francis
- external identifiers
-
- wos:000229592400002
- scopus:19944400754
- ISSN
- 0003-2719
- DOI
- 10.1081/AL-200057192
- language
- English
- LU publication?
- yes
- id
- 8733e8cf-786d-422e-bd22-f4d56eb577a0 (old id 155160)
- alternative location
- http://www.informaworld.com/smpp/content~content=a714010751~db=all
- date added to LUP
- 2016-04-01 17:01:17
- date last changed
- 2022-01-28 23:50:09
@article{8733e8cf-786d-422e-bd22-f4d56eb577a0, abstract = {{A flow injection cell-based biosensor was constructed for 2,4-dichlorophenol (DCP) analysis by using a Clark-type oxygen electrode as a transducer. A mixed bacterial culture capable to biodegrade DCP was immobilized between a Teflon membrane and a dialysis membrane and attached to the oxygen electrode. Optimization of the flow rate, the injection volume, the carrier buffer concentration, and pH was carried out. Under optimum conditions (100 mM phosphate buffer, pH 7.50; flow rate 0.10 mL min(-1); sample volume 100 mL), the sensor response was linear between 0.01 and 0.30 mM DCP. The detection limit was 0.02 mM DCP, and the sensor was quite stable during 5 days of operation.}}, author = {{Jantra, Jongjit and Zilouei, Hamid and Liu, Jing and Guieysse, Benoit and Thavarungkul, P and Kanatharana, P and Mattiasson, Bo}}, issn = {{0003-2719}}, language = {{eng}}, number = {{7}}, pages = {{1071--1083}}, publisher = {{Taylor & Francis}}, series = {{Analytical Letters}}, title = {{Microbial biosensor for the analysis of 2,4-dichlorophenol}}, url = {{http://dx.doi.org/10.1081/AL-200057192}}, doi = {{10.1081/AL-200057192}}, volume = {{38}}, year = {{2005}}, }