Performance of an On-Demand Beam Excitation System for PIXE Analysis

Malmqvist, Klas LU ; Karlsson, Erik and Akselsson, Roland LU (1982) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 192(2-3). p.523-532
Abstract
A system for electrostatic on-demand beam excitation in PIXE analysis has been built and carefully tested. Significantly increased count rate capability without any need for corrections for electronic dead time and with less target deterioration makes the system superior to a traditional system with electronic pile-up rejection. By adding a fast external electronic pulse pile-up rejection system, a pile-up interval of about 250 ns is obtained. The detailed behaviour of the particle beam during deflection and experience from using the system in routine analysis are reported.
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
PIXE, on-demand beam
in
Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
volume
192
issue
2-3
pages
523 - 532
publisher
Elsevier
external identifiers
  • scopus:0020087664
ISSN
0167-5087
DOI
10.1016/0029-554X(82)90867-9
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Ergonomics and Aerosol Technology (011025002), Nuclear Physics (Faculty of Technology) (011013007)
id
637e275f-2ae1-4fe2-a444-46cdf7540246 (old id 1745080)
date added to LUP
2016-04-01 16:02:29
date last changed
2021-01-03 03:48:22
@article{637e275f-2ae1-4fe2-a444-46cdf7540246,
  abstract     = {{A system for electrostatic on-demand beam excitation in PIXE analysis has been built and carefully tested. Significantly increased count rate capability without any need for corrections for electronic dead time and with less target deterioration makes the system superior to a traditional system with electronic pile-up rejection. By adding a fast external electronic pulse pile-up rejection system, a pile-up interval of about 250 ns is obtained. The detailed behaviour of the particle beam during deflection and experience from using the system in routine analysis are reported.}},
  author       = {{Malmqvist, Klas and Karlsson, Erik and Akselsson, Roland}},
  issn         = {{0167-5087}},
  keywords     = {{PIXE; on-demand beam}},
  language     = {{eng}},
  number       = {{2-3}},
  pages        = {{523--532}},
  publisher    = {{Elsevier}},
  series       = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}},
  title        = {{Performance of an On-Demand Beam Excitation System for PIXE Analysis}},
  url          = {{http://dx.doi.org/10.1016/0029-554X(82)90867-9}},
  doi          = {{10.1016/0029-554X(82)90867-9}},
  volume       = {{192}},
  year         = {{1982}},
}