Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Evaluation of cystatin C with iohexol clearance in cardiac surgery.

Brondén, Björn LU ; Eyjolfsson, Atli LU ; Blomquist, Sten LU ; Dardashti, A ; Ederoth, Per LU and Bjursten, Henrik LU (2011) In Acta Anaesthesiologica Scandinavica 55(2). p.196-202
Abstract
Post-operative renal dysfunction after cardiac surgery is not uncommon and can lead to adverse outcome. The ability to accurately monitor renal function is therefore important. Cystatin C is known to be a sensitive marker of the glomerular filtration rate (GFR), but it has not been fully evaluated in cardiac surgery. Iohexol clearance is considered a reliable reference method for the determination of GFR. The aim of this study is to, for the first time, evaluate the diagnostic accuracy of plasma cystatin C compared with iohexol clearance in cardiac surgery.
Please use this url to cite or link to this publication:
author
; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Acta Anaesthesiologica Scandinavica
volume
55
issue
2
pages
196 - 202
publisher
Wiley-Blackwell
external identifiers
  • wos:000286208600008
  • pmid:21226861
  • scopus:78651498187
  • pmid:21226861
ISSN
0001-5172
DOI
10.1111/j.1399-6576.2010.02361.x
language
English
LU publication?
yes
id
09497e76-3578-4af8-8705-6cacef953d5d (old id 1777579)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/21226861?dopt=Abstract
date added to LUP
2016-04-04 07:15:52
date last changed
2022-01-29 02:00:23
@article{09497e76-3578-4af8-8705-6cacef953d5d,
  abstract     = {{Post-operative renal dysfunction after cardiac surgery is not uncommon and can lead to adverse outcome. The ability to accurately monitor renal function is therefore important. Cystatin C is known to be a sensitive marker of the glomerular filtration rate (GFR), but it has not been fully evaluated in cardiac surgery. Iohexol clearance is considered a reliable reference method for the determination of GFR. The aim of this study is to, for the first time, evaluate the diagnostic accuracy of plasma cystatin C compared with iohexol clearance in cardiac surgery.}},
  author       = {{Brondén, Björn and Eyjolfsson, Atli and Blomquist, Sten and Dardashti, A and Ederoth, Per and Bjursten, Henrik}},
  issn         = {{0001-5172}},
  language     = {{eng}},
  number       = {{2}},
  pages        = {{196--202}},
  publisher    = {{Wiley-Blackwell}},
  series       = {{Acta Anaesthesiologica Scandinavica}},
  title        = {{Evaluation of cystatin C with iohexol clearance in cardiac surgery.}},
  url          = {{http://dx.doi.org/10.1111/j.1399-6576.2010.02361.x}},
  doi          = {{10.1111/j.1399-6576.2010.02361.x}},
  volume       = {{55}},
  year         = {{2011}},
}