Detection of body position changes using the surface electrocardiogram

Åström, Magnus LU ; Garcia, J ; Laguna, P ; Pahlm, Olle LU and Sörnmo, Leif LU (2003) In Medical & Biological Engineering & Computing 41(2). p.164-171
Abstract
A method for detecting body position changes that uses the surface vectorcardiogram (VCG) is presented. Such changes are often manifested as sudden shifts in the electrical axis of the heart and can erroneously be interpreted as acute ischaemic events. Axis shifts were detected by analysing the rotation angles obtained from the alignment of successive VCG loops to a reference loop. Following the rejection of angles originating from noise events, the detection of body position changes was performed on the angle series using a Bayesian approach. On a database of ECG recordings from normal subjects performing a predefined sequence of body position changes, a detection rate of 92% and a false alarm rate of 7% was achieved.
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
rotation angles, VCG loops, loop alignment, body position, ischaemia monitoring
in
Medical & Biological Engineering & Computing
volume
41
issue
2
pages
164 - 171
publisher
Springer
external identifiers
  • wos:000182244900007
  • scopus:0242417005
ISSN
0140-0118
DOI
10.1007/BF02344884
language
English
LU publication?
yes
id
1d0b48ab-da6d-4a93-a4f7-9b2c17047af8 (old id 313305)
date added to LUP
2016-04-01 15:37:57
date last changed
2022-01-28 06:16:37
@article{1d0b48ab-da6d-4a93-a4f7-9b2c17047af8,
  abstract     = {{A method for detecting body position changes that uses the surface vectorcardiogram (VCG) is presented. Such changes are often manifested as sudden shifts in the electrical axis of the heart and can erroneously be interpreted as acute ischaemic events. Axis shifts were detected by analysing the rotation angles obtained from the alignment of successive VCG loops to a reference loop. Following the rejection of angles originating from noise events, the detection of body position changes was performed on the angle series using a Bayesian approach. On a database of ECG recordings from normal subjects performing a predefined sequence of body position changes, a detection rate of 92% and a false alarm rate of 7% was achieved.}},
  author       = {{Åström, Magnus and Garcia, J and Laguna, P and Pahlm, Olle and Sörnmo, Leif}},
  issn         = {{0140-0118}},
  keywords     = {{rotation angles; VCG loops; loop alignment; body position; ischaemia monitoring}},
  language     = {{eng}},
  number       = {{2}},
  pages        = {{164--171}},
  publisher    = {{Springer}},
  series       = {{Medical & Biological Engineering & Computing}},
  title        = {{Detection of body position changes using the surface electrocardiogram}},
  url          = {{http://dx.doi.org/10.1007/BF02344884}},
  doi          = {{10.1007/BF02344884}},
  volume       = {{41}},
  year         = {{2003}},
}