Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Comparison of short axis and long axis acquisitions of T1 and extracellular volume mapping using MOLLI and SASHA in patients with myocardial infarction and healthy volunteers

Xanthis, Christos G. LU ; Nordlund, David LU ; Jablonowski, Robert LU and Arheden, Håkan LU (2019) In BMC Medical Imaging 19(1).
Abstract

Background: Although previous studies have examined the impact of slice position in volumetric measurements in Cardiovascular Magnetic Resonance (CMR) imaging, very limited data are available today comparing T1 and Extra-Cellular Volume (ECV) measurements from short and long axis acquisitions. The purpose of this study was to investigate the impact of slice position and orientation on T1 and ECV measurements using the MOdified Look-Locker Inversion recovery (MOLLI) and Saturation recovery single-shot acquisition (SASHA) sequence in patients with myocardial infarction and in healthy volunteers. Methods: Eight (8) healthy volunteers with no medical history and eight (8) patients with myocardial infarction were included in this study.... (More)

Background: Although previous studies have examined the impact of slice position in volumetric measurements in Cardiovascular Magnetic Resonance (CMR) imaging, very limited data are available today comparing T1 and Extra-Cellular Volume (ECV) measurements from short and long axis acquisitions. The purpose of this study was to investigate the impact of slice position and orientation on T1 and ECV measurements using the MOdified Look-Locker Inversion recovery (MOLLI) and Saturation recovery single-shot acquisition (SASHA) sequence in patients with myocardial infarction and in healthy volunteers. Methods: Eight (8) healthy volunteers with no medical history and eight (8) patients with myocardial infarction were included in this study. MOLLI and SASHA were utilized and short-axis and long-axis images were acquired. T1 and ECV measurements were performed by drawing same size regions of interest on the myocardium as well in the blood pool at the intersections of the short axis and long axis images. Results: In healthy volunteers, there were no statistically significant differences in native T1 and ECV values between short axis and long axis acquisitions using MOLLI (two-chamber, three-chamber and four-chamber) and SASHA (three-chamber). In patients, there were no statistically significant differences in native T1 and ECV values between short axis and 3-chamber long axis acquisitions in both remote and affected myocardium using MOLLI and SASHA. Conclusions: Long axis measurements of myocardial T1 and ECV using MOLLI and SASHA exhibit good agreement with the corresponding short axis measurements allowing for fast and reliable myocardial tissue characterization in cases where shortening of the overall imaging acquisition is required.

(Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Cardiovascular magnetic resonance, Extracellular volume, MOLLI, SASHA, Slice orientation, T1 mapping
in
BMC Medical Imaging
volume
19
issue
1
article number
18
publisher
BioMed Central (BMC)
external identifiers
  • scopus:85062039987
  • pmid:30795746
ISSN
1471-2342
DOI
10.1186/s12880-019-0320-x
language
English
LU publication?
yes
id
31bf6fd4-2587-4f34-b3fe-4ac9b9551d96
date added to LUP
2019-03-06 10:46:24
date last changed
2024-03-02 21:24:59
@article{31bf6fd4-2587-4f34-b3fe-4ac9b9551d96,
  abstract     = {{<p>Background: Although previous studies have examined the impact of slice position in volumetric measurements in Cardiovascular Magnetic Resonance (CMR) imaging, very limited data are available today comparing T1 and Extra-Cellular Volume (ECV) measurements from short and long axis acquisitions. The purpose of this study was to investigate the impact of slice position and orientation on T1 and ECV measurements using the MOdified Look-Locker Inversion recovery (MOLLI) and Saturation recovery single-shot acquisition (SASHA) sequence in patients with myocardial infarction and in healthy volunteers. Methods: Eight (8) healthy volunteers with no medical history and eight (8) patients with myocardial infarction were included in this study. MOLLI and SASHA were utilized and short-axis and long-axis images were acquired. T1 and ECV measurements were performed by drawing same size regions of interest on the myocardium as well in the blood pool at the intersections of the short axis and long axis images. Results: In healthy volunteers, there were no statistically significant differences in native T1 and ECV values between short axis and long axis acquisitions using MOLLI (two-chamber, three-chamber and four-chamber) and SASHA (three-chamber). In patients, there were no statistically significant differences in native T1 and ECV values between short axis and 3-chamber long axis acquisitions in both remote and affected myocardium using MOLLI and SASHA. Conclusions: Long axis measurements of myocardial T1 and ECV using MOLLI and SASHA exhibit good agreement with the corresponding short axis measurements allowing for fast and reliable myocardial tissue characterization in cases where shortening of the overall imaging acquisition is required.</p>}},
  author       = {{Xanthis, Christos G. and Nordlund, David and Jablonowski, Robert and Arheden, Håkan}},
  issn         = {{1471-2342}},
  keywords     = {{Cardiovascular magnetic resonance; Extracellular volume; MOLLI; SASHA; Slice orientation; T1 mapping}},
  language     = {{eng}},
  month        = {{02}},
  number       = {{1}},
  publisher    = {{BioMed Central (BMC)}},
  series       = {{BMC Medical Imaging}},
  title        = {{Comparison of short axis and long axis acquisitions of T1 and extracellular volume mapping using MOLLI and SASHA in patients with myocardial infarction and healthy volunteers}},
  url          = {{http://dx.doi.org/10.1186/s12880-019-0320-x}},
  doi          = {{10.1186/s12880-019-0320-x}},
  volume       = {{19}},
  year         = {{2019}},
}