Generalized adiabatic pressure drop correlations in evaporative micro/mini-channels

Li, Wei and Wu, Zan LU (2011) In Experimental Thermal and Fluid Science 35(6). p.866-872
Abstract
Existing database in literature on the adiabatic two-phase frictional pressure drop in evaporative micro/mini-channels were reviewed. The collected database contains 769 data points, covering 12 fluids, for a wide range of operational conditions and channel dimensions. The whole database was analyzed using five existing correlations to verify their respective accuracies. The importance of the Bond number, which relates the nominal bubble dimension or capillary parameter with the channel size, was revealed. A particular trend was observed with the Bond number that distinguished the entire database into three ranges. Using the Bond number, improved correlations of adiabatic two-phase pressure drop were established for small Bond number... (More)
Existing database in literature on the adiabatic two-phase frictional pressure drop in evaporative micro/mini-channels were reviewed. The collected database contains 769 data points, covering 12 fluids, for a wide range of operational conditions and channel dimensions. The whole database was analyzed using five existing correlations to verify their respective accuracies. The importance of the Bond number, which relates the nominal bubble dimension or capillary parameter with the channel size, was revealed. A particular trend was observed with the Bond number that distinguished the entire database into three ranges. Using the Bond number, improved correlations of adiabatic two-phase pressure drop were established for small Bond number regions. The newly proposed correlations can predict the database well for the region where BoRel0.5 ≤ 200 (Less)
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Bond number, Chisholm parameter, Micro-channel, Pressure drop, Two-phase multiplier
in
Experimental Thermal and Fluid Science
volume
35
issue
6
pages
866 - 872
publisher
Elsevier
external identifiers
  • scopus:79957599437
ISSN
1879-2286
language
English
LU publication?
no
id
f6911cf5-da9f-43ce-91ad-21cd0898e116 (old id 4285425)
date added to LUP
2016-04-01 11:16:45
date last changed
2022-02-03 01:11:43
@article{f6911cf5-da9f-43ce-91ad-21cd0898e116,
  abstract     = {{Existing database in literature on the adiabatic two-phase frictional pressure drop in evaporative micro/mini-channels were reviewed. The collected database contains 769 data points, covering 12 fluids, for a wide range of operational conditions and channel dimensions. The whole database was analyzed using five existing correlations to verify their respective accuracies. The importance of the Bond number, which relates the nominal bubble dimension or capillary parameter with the channel size, was revealed. A particular trend was observed with the Bond number that distinguished the entire database into three ranges. Using the Bond number, improved correlations of adiabatic two-phase pressure drop were established for small Bond number regions. The newly proposed correlations can predict the database well for the region where BoRel0.5 ≤ 200}},
  author       = {{Li, Wei and Wu, Zan}},
  issn         = {{1879-2286}},
  keywords     = {{Bond number; Chisholm parameter; Micro-channel; Pressure drop; Two-phase multiplier}},
  language     = {{eng}},
  number       = {{6}},
  pages        = {{866--872}},
  publisher    = {{Elsevier}},
  series       = {{Experimental Thermal and Fluid Science}},
  title        = {{Generalized adiabatic pressure drop correlations in evaporative micro/mini-channels}},
  volume       = {{35}},
  year         = {{2011}},
}