Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

The added value of hybrid ventilation/perfusion SPECT/CT in patients with stable COPD or apparently healthy smokers. Cancer-suspected CT findings in the lungs are common when hybrid imaging is used

Jögi, Jonas LU orcid ; Markstad, Hanna LU ; Tufvesson, Ellen LU ; Bjermer, Leif LU and Bajc, Marika LU (2015) In The International Journal of Chronic Obstructive Pulmonary Disease 10. p.25-30
Abstract
Ventilation/perfusion (V/P) single-photon emission computed tomography (SPECT) is recognized as a diagnostic method with potential beyond the diagnosis of pulmonary embolism. V/P SPECT identifies functional impairment in diseases such as heart failure (HF), pneumonia, and chronic obstructive pulmonary disease (COPD). The development of hybrid SPECT/computed tomography (CT) systems, combining functional with morphological imaging through the addition of low-dose CT (LDCT), may be useful in COPD, as these patients are prone to lung cancer and other comorbidities. The aim of this study was to investigate the added value of LDCT among healthy smokers and patients with stable COPD, when examined with V/P SPECT/CT hybrid imaging. Sixty-nine... (More)
Ventilation/perfusion (V/P) single-photon emission computed tomography (SPECT) is recognized as a diagnostic method with potential beyond the diagnosis of pulmonary embolism. V/P SPECT identifies functional impairment in diseases such as heart failure (HF), pneumonia, and chronic obstructive pulmonary disease (COPD). The development of hybrid SPECT/computed tomography (CT) systems, combining functional with morphological imaging through the addition of low-dose CT (LDCT), may be useful in COPD, as these patients are prone to lung cancer and other comorbidities. The aim of this study was to investigate the added value of LDCT among healthy smokers and patients with stable COPD, when examined with V/P SPECT/CT hybrid imaging. Sixty-nine subjects, 55 with COPD (GOLD I-IV) and 14 apparently healthy smokers, were examined with V/P SPECT and LDCT hybrid imaging. Spirometry was used to verify COPD grade. Only one apparently healthy smoker and three COPD patients had a normal or nearly normal V/P SPECT. All other patients showed various degrees of airway obstruction, even when spirometry was normal. The same interpretation was reached on both modalities in 39% of the patients. LDCT made V/P SPECT interpretation more certain in 9% of the patients and, in 52%, LDCT provided additional diagnoses. LDCT better characterized the type of emphysema in 12 patients. In 19 cases, tumor-suspected changes were reported. Three of these 19 patients (ie, 4.3% of all subjects) were in the end confirmed to have lung cancer. The majority of LDCT findings were not regarded as clinically significant. V/P SPECT identified perfusion patterns consistent with decompensated left ventricular HF in 14 COPD patients. In 16 patients (23%), perfusion defects were observed. HF and perfusion defects were not recognized with LDCT. In COPD patients and long-time smokers, hybrid imaging had added value compared to V/P SPECT alone, by identifying patients with lung malignancy and more clearly identifying emphysema. V/P SPECT visualizes comorbidities to COPD not seen with LDCT, such as pulmonary embolism and left ventricular HF. (Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
lung, lung cancer, V/P SPECT, ventilation/perfusion, single-photon, emission computed tomography, computed tomography
in
The International Journal of Chronic Obstructive Pulmonary Disease
volume
10
pages
25 - 30
publisher
Dove Medical Press Ltd.
external identifiers
  • wos:000346575900001
  • pmid:25565797
  • scopus:84919419789
  • pmid:25565797
ISSN
1178-2005
DOI
10.2147/COPD.S73423
language
English
LU publication?
yes
id
2c94870e-ef1d-4a96-9b9d-fcf4d3f20bdc (old id 4941586)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/25565797?dopt=Abstract
date added to LUP
2016-04-01 10:13:03
date last changed
2022-02-02 07:35:34
@article{2c94870e-ef1d-4a96-9b9d-fcf4d3f20bdc,
  abstract     = {{Ventilation/perfusion (V/P) single-photon emission computed tomography (SPECT) is recognized as a diagnostic method with potential beyond the diagnosis of pulmonary embolism. V/P SPECT identifies functional impairment in diseases such as heart failure (HF), pneumonia, and chronic obstructive pulmonary disease (COPD). The development of hybrid SPECT/computed tomography (CT) systems, combining functional with morphological imaging through the addition of low-dose CT (LDCT), may be useful in COPD, as these patients are prone to lung cancer and other comorbidities. The aim of this study was to investigate the added value of LDCT among healthy smokers and patients with stable COPD, when examined with V/P SPECT/CT hybrid imaging. Sixty-nine subjects, 55 with COPD (GOLD I-IV) and 14 apparently healthy smokers, were examined with V/P SPECT and LDCT hybrid imaging. Spirometry was used to verify COPD grade. Only one apparently healthy smoker and three COPD patients had a normal or nearly normal V/P SPECT. All other patients showed various degrees of airway obstruction, even when spirometry was normal. The same interpretation was reached on both modalities in 39% of the patients. LDCT made V/P SPECT interpretation more certain in 9% of the patients and, in 52%, LDCT provided additional diagnoses. LDCT better characterized the type of emphysema in 12 patients. In 19 cases, tumor-suspected changes were reported. Three of these 19 patients (ie, 4.3% of all subjects) were in the end confirmed to have lung cancer. The majority of LDCT findings were not regarded as clinically significant. V/P SPECT identified perfusion patterns consistent with decompensated left ventricular HF in 14 COPD patients. In 16 patients (23%), perfusion defects were observed. HF and perfusion defects were not recognized with LDCT. In COPD patients and long-time smokers, hybrid imaging had added value compared to V/P SPECT alone, by identifying patients with lung malignancy and more clearly identifying emphysema. V/P SPECT visualizes comorbidities to COPD not seen with LDCT, such as pulmonary embolism and left ventricular HF.}},
  author       = {{Jögi, Jonas and Markstad, Hanna and Tufvesson, Ellen and Bjermer, Leif and Bajc, Marika}},
  issn         = {{1178-2005}},
  keywords     = {{lung; lung cancer; V/P SPECT; ventilation/perfusion; single-photon; emission computed tomography; computed tomography}},
  language     = {{eng}},
  pages        = {{25--30}},
  publisher    = {{Dove Medical Press Ltd.}},
  series       = {{The International Journal of Chronic Obstructive Pulmonary Disease}},
  title        = {{The added value of hybrid ventilation/perfusion SPECT/CT in patients with stable COPD or apparently healthy smokers. Cancer-suspected CT findings in the lungs are common when hybrid imaging is used}},
  url          = {{https://lup.lub.lu.se/search/files/1658895/8058352.pdf}},
  doi          = {{10.2147/COPD.S73423}},
  volume       = {{10}},
  year         = {{2015}},
}