A Probing Control Strategy: Stability and Performance
(2004) 5. p.4607-4612- Abstract
- An extremum controller based on a pulse technique is examined. Plants consisting of the cascade of a piecewise linear static function and a LTI system are considered. Numerical methods for stability and performance analysis of the closed-loop systems are derived. Performance is measured by the ability to track a time-varying optimal point. An illustrative example where it is desirable to control theprocess to a saturation instead of an extremum is finally presented.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/536057
- author
- Velut, Stéphane LU and Hagander, Per LU
- organization
- publishing date
- 2004
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- probing control strategy, time-varying optimal point tracking, piecewise linear static function, performance analysis, numerical methods, extremum controller, closed-loop systems, cascade, LTI system, saturation, pulse technique, stability analysis, time-varying systems
- host publication
- Proceedings 43rd IEEE Conference on Decision and Control
- volume
- 5
- pages
- 4607 - 4612
- publisher
- IEEE - Institute of Electrical and Electronics Engineers Inc.
- external identifiers
-
- wos:000226745604016
- scopus:14544288746
- ISSN
- 0191-2216
- ISBN
- 0-7803-8682-5
- DOI
- 10.1109/CDC.2004.1429510
- language
- English
- LU publication?
- yes
- id
- aa6e631a-16bb-466e-b62c-f4de2a152bf0 (old id 536057)
- date added to LUP
- 2016-04-01 16:49:39
- date last changed
- 2022-03-15 03:11:28
@inproceedings{aa6e631a-16bb-466e-b62c-f4de2a152bf0, abstract = {{An extremum controller based on a pulse technique is examined. Plants consisting of the cascade of a piecewise linear static function and a LTI system are considered. Numerical methods for stability and performance analysis of the closed-loop systems are derived. Performance is measured by the ability to track a time-varying optimal point. An illustrative example where it is desirable to control theprocess to a saturation instead of an extremum is finally presented.}}, author = {{Velut, Stéphane and Hagander, Per}}, booktitle = {{Proceedings 43rd IEEE Conference on Decision and Control}}, isbn = {{0-7803-8682-5}}, issn = {{0191-2216}}, keywords = {{probing control strategy; time-varying optimal point tracking; piecewise linear static function; performance analysis; numerical methods; extremum controller; closed-loop systems; cascade; LTI system; saturation; pulse technique; stability analysis; time-varying systems}}, language = {{eng}}, pages = {{4607--4612}}, publisher = {{IEEE - Institute of Electrical and Electronics Engineers Inc.}}, title = {{A Probing Control Strategy: Stability and Performance}}, url = {{https://lup.lub.lu.se/search/files/4792240/625611.pdf}}, doi = {{10.1109/CDC.2004.1429510}}, volume = {{5}}, year = {{2004}}, }