Interlaboratory tests on thermal foot models

Kuklane, Kalev LU and Holmér, Ingvar LU (2001) 4th International Meeting on Thermal Manikins (4I3M)
Abstract
In order to compare measurements in different laboratories and with different models and measuring principles a small Round Robin test was suggested. 8 test institutions were able to join the study (with foot model sizes from 254 mm to 275 mm and test boot sizes from 41 to 44). We got also a declaration of interest from several other institutes that were not able to carry out the tests. A database was made for study results, thus making it possible to add test results from other test laboratories and on other footwear later on.

The test series were carried out under standardised conditions in each laboratory. Ten (10) test conditions were recommended. All conditions had to be tested twice. Tests with naked foot and sock were... (More)
In order to compare measurements in different laboratories and with different models and measuring principles a small Round Robin test was suggested. 8 test institutions were able to join the study (with foot model sizes from 254 mm to 275 mm and test boot sizes from 41 to 44). We got also a declaration of interest from several other institutes that were not able to carry out the tests. A database was made for study results, thus making it possible to add test results from other test laboratories and on other footwear later on.

The test series were carried out under standardised conditions in each laboratory. Ten (10) test conditions were recommended. All conditions had to be tested twice. Tests with naked foot and sock were carried out at about +20 °C and 50 % RH. The rest conditions were tested at about +5 °C and 85 % RH. The conditioning was done at 20±2 °C and 35±5 % RH. Air velocity was kept low (<0.3 m/s). Participants were asked to carry out as many tests as they could from the list and skip those they were not able to do. If something in test conditions had to be changed, a note was made on that.

The test series was meant to be a basis for applying for a project further on that should aim to suggest changes in existing European standard (EN 344) or propose a new (international) standard on footwear thermal testing. (Less)
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
host publication
Proceedings of the 4th International Meeting on Thermal Manikins (4I3M)
editor
Richards, Mark
pages
5 pages
publisher
EMPA
conference name
4th International Meeting on Thermal Manikins (4I3M)
conference location
St. Gallen, Switzerland
conference dates
2001-09-27 - 2001-09-28
language
English
LU publication?
no
additional info
Available on CD only
id
6eaed331-a7c1-472e-accf-c580f21b252d (old id 635697)
date added to LUP
2016-04-04 10:53:18
date last changed
2018-11-21 21:01:22
@inproceedings{6eaed331-a7c1-472e-accf-c580f21b252d,
  abstract     = {{In order to compare measurements in different laboratories and with different models and measuring principles a small Round Robin test was suggested. 8 test institutions were able to join the study (with foot model sizes from 254 mm to 275 mm and test boot sizes from 41 to 44). We got also a declaration of interest from several other institutes that were not able to carry out the tests. A database was made for study results, thus making it possible to add test results from other test laboratories and on other footwear later on.<br/><br>
The test series were carried out under standardised conditions in each laboratory. Ten (10) test conditions were recommended. All conditions had to be tested twice. Tests with naked foot and sock were carried out at about +20 °C and 50 % RH. The rest conditions were tested at about +5 °C and 85 % RH. The conditioning was done at 20±2 °C and 35±5 % RH. Air velocity was kept low (&lt;0.3 m/s). Participants were asked to carry out as many tests as they could from the list and skip those they were not able to do. If something in test conditions had to be changed, a note was made on that.<br/><br>
The test series was meant to be a basis for applying for a project further on that should aim to suggest changes in existing European standard (EN 344) or propose a new (international) standard on footwear thermal testing.}},
  author       = {{Kuklane, Kalev and Holmér, Ingvar}},
  booktitle    = {{Proceedings of the 4th International Meeting on Thermal Manikins (4I3M)}},
  editor       = {{Richards, Mark}},
  language     = {{eng}},
  publisher    = {{EMPA}},
  title        = {{Interlaboratory tests on thermal foot models}},
  year         = {{2001}},
}