Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Sonography in total hip arthroplasty

Tarasevicius, S. ; Skikas, L. ; Mitraite, D. ; Torii, Y. ; Kesteris, Uldis LU and Wingstrand, Hans LU (2007) In Ultraschall in der Medizin 28(5). p.475-478
Abstract
Purpose: The distance between the anterior surface of the neck of the prosthetic stem and the anterior joint capsule, the "capsular distance", is increased in total hip arthroplasty (THA) with synovitis. We evaluated the potential of ultrasonography (US) in measuring the "capsular distance" in THA hips one year after insertion. Materials and Methods: We compared the measurements of the capsular distance using a ruler with those performed with US. A plastic pelvis and femur model with a prosthetic hip and paper tape to simulate the joint capsule were used. We also evaluated the intra- and interobserver agreements between 3 examiners of the US measurements of the anterior capsular distance in 22 patients with THA. The effect of experience in... (More)
Purpose: The distance between the anterior surface of the neck of the prosthetic stem and the anterior joint capsule, the "capsular distance", is increased in total hip arthroplasty (THA) with synovitis. We evaluated the potential of ultrasonography (US) in measuring the "capsular distance" in THA hips one year after insertion. Materials and Methods: We compared the measurements of the capsular distance using a ruler with those performed with US. A plastic pelvis and femur model with a prosthetic hip and paper tape to simulate the joint capsule were used. We also evaluated the intra- and interobserver agreements between 3 examiners of the US measurements of the anterior capsular distance in 22 patients with THA. The effect of experience in such type of examination was estimated. Results: There was a high correlation when measuring the anterior capsular distance in the prosthetic hip model with a ruler as compared with US. The interobserver agreement in the US measurements was good and became better after examiners gained experience in this procedure. The intraobserver agreement was always better than the interobserver agreement and also improved with increasing numbers of examinations. Conclusion: Ultrasonography is a reliable method to measure the anterior capsular distance in THA, especially if performed by an experienced examiner. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
total hip arthroplasty, ultrasound, capsular distance
in
Ultraschall in der Medizin
volume
28
issue
5
pages
475 - 478
publisher
Georg Thieme Verlag
external identifiers
  • wos:000250554700005
  • scopus:35648979982
ISSN
0172-4614
DOI
10.1055/s-2007-963287
language
English
LU publication?
yes
id
08f5a0bf-9542-43e8-aaa9-df1c63a10e91 (old id 651731)
date added to LUP
2016-04-01 16:49:06
date last changed
2022-03-22 21:24:41
@article{08f5a0bf-9542-43e8-aaa9-df1c63a10e91,
  abstract     = {{Purpose: The distance between the anterior surface of the neck of the prosthetic stem and the anterior joint capsule, the "capsular distance", is increased in total hip arthroplasty (THA) with synovitis. We evaluated the potential of ultrasonography (US) in measuring the "capsular distance" in THA hips one year after insertion. Materials and Methods: We compared the measurements of the capsular distance using a ruler with those performed with US. A plastic pelvis and femur model with a prosthetic hip and paper tape to simulate the joint capsule were used. We also evaluated the intra- and interobserver agreements between 3 examiners of the US measurements of the anterior capsular distance in 22 patients with THA. The effect of experience in such type of examination was estimated. Results: There was a high correlation when measuring the anterior capsular distance in the prosthetic hip model with a ruler as compared with US. The interobserver agreement in the US measurements was good and became better after examiners gained experience in this procedure. The intraobserver agreement was always better than the interobserver agreement and also improved with increasing numbers of examinations. Conclusion: Ultrasonography is a reliable method to measure the anterior capsular distance in THA, especially if performed by an experienced examiner.}},
  author       = {{Tarasevicius, S. and Skikas, L. and Mitraite, D. and Torii, Y. and Kesteris, Uldis and Wingstrand, Hans}},
  issn         = {{0172-4614}},
  keywords     = {{total hip arthroplasty; ultrasound; capsular distance}},
  language     = {{eng}},
  number       = {{5}},
  pages        = {{475--478}},
  publisher    = {{Georg Thieme Verlag}},
  series       = {{Ultraschall in der Medizin}},
  title        = {{Sonography in total hip arthroplasty}},
  url          = {{http://dx.doi.org/10.1055/s-2007-963287}},
  doi          = {{10.1055/s-2007-963287}},
  volume       = {{28}},
  year         = {{2007}},
}