Pulse wave analysis by digital photoplethysmography to record maternal hemodynamic effects of spinal anesthesia, delivery of the baby, and intravenous oxytocin during cesarean section

Rabow, Sofus LU and Olofsson, Per LU (2017) In Journal of Maternal-Fetal & Neonatal Medicine 30(7). p.759-766
Abstract

Objective: To investigate changes in maternal ECG ST index, blood pressure (BP), cardiac left ventricular (LV) ejection function and vascular tone/stiffness in large and small arteries occurring during elective cesarean section (CS) in spinal anesthesia. Material and methods: Twenty-six women were monitored with photoplethysmographic digital pulse wave (PW) analysis (DPA) before and after spinal anesthesia, after delivery of the baby, after 5 IU oxytocin bolus IV, and 5 min later. Statistics with Wilcoxon matched-pairs signed-rank and Friedman tests at a p 

Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Arterial elasticity, arterial stiffness, oxytocin, pregnancy, pulse wave analysis, spinal anesthesia
in
Journal of Maternal-Fetal & Neonatal Medicine
volume
30
issue
7
pages
759 - 766
publisher
Taylor & Francis
external identifiers
  • scopus:84969836764
  • pmid:27145830
  • wos:000399742300001
ISSN
1476-7058
DOI
10.1080/14767058.2016.1186162
language
English
LU publication?
yes
id
881f17ea-246a-4874-af6e-3c56c4c8116d
date added to LUP
2016-06-17 15:53:24
date last changed
2024-02-18 23:03:00
@article{881f17ea-246a-4874-af6e-3c56c4c8116d,
  abstract     = {{<p>Objective: To investigate changes in maternal ECG ST index, blood pressure (BP), cardiac left ventricular (LV) ejection function and vascular tone/stiffness in large and small arteries occurring during elective cesarean section (CS) in spinal anesthesia. Material and methods: Twenty-six women were monitored with photoplethysmographic digital pulse wave (PW) analysis (DPA) before and after spinal anesthesia, after delivery of the baby, after 5 IU oxytocin bolus IV, and 5 min later. Statistics with Wilcoxon matched-pairs signed-rank and Friedman tests at a p </p>}},
  author       = {{Rabow, Sofus and Olofsson, Per}},
  issn         = {{1476-7058}},
  keywords     = {{Arterial elasticity; arterial stiffness; oxytocin; pregnancy; pulse wave analysis; spinal anesthesia}},
  language     = {{eng}},
  number       = {{7}},
  pages        = {{759--766}},
  publisher    = {{Taylor & Francis}},
  series       = {{Journal of Maternal-Fetal & Neonatal Medicine}},
  title        = {{Pulse wave analysis by digital photoplethysmography to record maternal hemodynamic effects of spinal anesthesia, delivery of the baby, and intravenous oxytocin during cesarean section}},
  url          = {{https://lup.lub.lu.se/search/files/13534117/8476978.pdf}},
  doi          = {{10.1080/14767058.2016.1186162}},
  volume       = {{30}},
  year         = {{2017}},
}