Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Hysteresis and transient behavior in current-voltage measurements of hybrid-perovskite absorber solar cells

Unger, E. L. LU ; Hoke, E. T. ; Bailie, C. D. ; Nguyen, W. H. ; Bowring, A. R. ; Heumüller, T. ; Christoforo, M. G. and McGehee, M. D. (2014) In Energy and Environmental Science 7(11). p.3690-3698
Abstract

Hybrid organo-metal halide perovskites are an exciting new class of solar absorber materials and have exhibited a rapid increase in solar cell efficiencies throughout the past two years to over 17% in both meso-structured and thin-film device architectures. We observe slow transient effects causing hysteresis in the current-voltage characterization of these devices that can lead to an over- or underestimation of the solar cell device efficiency. We find that the current-voltage (IV) measurement scan direction, measurement delay time, and light and voltage bias conditions prior to measurement can all have a significant impact upon the shape of the measured IV light curves and the apparent device efficiency. We observe that... (More)

Hybrid organo-metal halide perovskites are an exciting new class of solar absorber materials and have exhibited a rapid increase in solar cell efficiencies throughout the past two years to over 17% in both meso-structured and thin-film device architectures. We observe slow transient effects causing hysteresis in the current-voltage characterization of these devices that can lead to an over- or underestimation of the solar cell device efficiency. We find that the current-voltage (IV) measurement scan direction, measurement delay time, and light and voltage bias conditions prior to measurement can all have a significant impact upon the shape of the measured IV light curves and the apparent device efficiency. We observe that hysteresis-free light IV curves can be obtained at both extremely fast and slow voltage scan rates but only in the latter case are quasi-steady-state conditions achieved for a valid power conversion efficiency measurement. Hysteretic effects are also observed in devices utilizing alternative selective contacts but differ in magnitude and time scale, suggesting that the contact interfaces have a big effect on transients in perovskite-absorber devices. The transient processes giving rise to hysteresis are consistent with a polarization response of the perovskite absorber that results in changes in the photocurrent extraction efficiency of the device. The strong dependence of the hysteresis on light and voltage biasing conditions in thin film devices for a period of time prior to the measurement suggests that photo-induced ion migration may additionally play an important role in device hysteresis. Based on these observations, we provide recommendations for correct measurement and reporting of IV curves for perovskite solar cell devices.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; and
publishing date
type
Contribution to journal
publication status
published
in
Energy and Environmental Science
volume
7
issue
11
pages
9 pages
publisher
Royal Society of Chemistry
external identifiers
  • scopus:84907965045
ISSN
1754-5692
DOI
10.1039/c4ee02465f
language
English
LU publication?
no
id
b754872b-4a92-4482-8743-189040a0a546
date added to LUP
2020-01-19 15:00:42
date last changed
2022-04-18 19:59:51
@article{b754872b-4a92-4482-8743-189040a0a546,
  abstract     = {{<p>Hybrid organo-metal halide perovskites are an exciting new class of solar absorber materials and have exhibited a rapid increase in solar cell efficiencies throughout the past two years to over 17% in both meso-structured and thin-film device architectures. We observe slow transient effects causing hysteresis in the current-voltage characterization of these devices that can lead to an over- or underestimation of the solar cell device efficiency. We find that the current-voltage (IV) measurement scan direction, measurement delay time, and light and voltage bias conditions prior to measurement can all have a significant impact upon the shape of the measured IV light curves and the apparent device efficiency. We observe that hysteresis-free light IV curves can be obtained at both extremely fast and slow voltage scan rates but only in the latter case are quasi-steady-state conditions achieved for a valid power conversion efficiency measurement. Hysteretic effects are also observed in devices utilizing alternative selective contacts but differ in magnitude and time scale, suggesting that the contact interfaces have a big effect on transients in perovskite-absorber devices. The transient processes giving rise to hysteresis are consistent with a polarization response of the perovskite absorber that results in changes in the photocurrent extraction efficiency of the device. The strong dependence of the hysteresis on light and voltage biasing conditions in thin film devices for a period of time prior to the measurement suggests that photo-induced ion migration may additionally play an important role in device hysteresis. Based on these observations, we provide recommendations for correct measurement and reporting of IV curves for perovskite solar cell devices.</p>}},
  author       = {{Unger, E. L. and Hoke, E. T. and Bailie, C. D. and Nguyen, W. H. and Bowring, A. R. and Heumüller, T. and Christoforo, M. G. and McGehee, M. D.}},
  issn         = {{1754-5692}},
  language     = {{eng}},
  month        = {{11}},
  number       = {{11}},
  pages        = {{3690--3698}},
  publisher    = {{Royal Society of Chemistry}},
  series       = {{Energy and Environmental Science}},
  title        = {{Hysteresis and transient behavior in current-voltage measurements of hybrid-perovskite absorber solar cells}},
  url          = {{http://dx.doi.org/10.1039/c4ee02465f}},
  doi          = {{10.1039/c4ee02465f}},
  volume       = {{7}},
  year         = {{2014}},
}