Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Perceived and measured indoor climate in new-family buildings including identifying technical deficiencies

Nordquist, Birgitta LU ; Fransson, Victor LU and Lindberg, Ola (2014) 10th Nordic Symposium in Building Physics In Rapport TVBH p.846-853
Abstract
When new buildings are constructed the indoor climate for the first period may differ from the one after some years due to various factors, for example may the emissions from the building materials be higher, possibly affecting the air quality, and the balancing of the technical systems; the mechanical supply and exhaust system and heating may not be completely finished. The perceived indoor climate in new-multi family buildings, with the aim of low-energy use and good indoor climate, has been examined by questionnaires when the buildings were new. In this follow-up study the same questionnaire has been performed after some years. Measurements of the indoor climate and the performance of the technical systems have also been made in some... (More)
When new buildings are constructed the indoor climate for the first period may differ from the one after some years due to various factors, for example may the emissions from the building materials be higher, possibly affecting the air quality, and the balancing of the technical systems; the mechanical supply and exhaust system and heating may not be completely finished. The perceived indoor climate in new-multi family buildings, with the aim of low-energy use and good indoor climate, has been examined by questionnaires when the buildings were new. In this follow-up study the same questionnaire has been performed after some years. Measurements of the indoor climate and the performance of the technical systems have also been made in some apartments. The objectives are to compare the resident’s experience of indoor climate after some years of occupancy with when the buildings were new and to examine indoor climate and aspects influencing this after some years of occupancy. One objective being studied is the window opening in the apartments and factors related to this. No large difference in experience is seen after some years. A majority of the respondents open their windows during the heating season for rather long time periods and daily or almost every day. It was found that the resulting indoor climate is a complex interaction between the technical systems, the design of the building envelope and the behavior of the occupant. Several deficiencies in all this three areas have been identified and suggestions on possible improvements are included. (Less)
Please use this url to cite or link to this publication:
author
; and
organization
alternative title
Upplevt och uppmätt inomhusklimat i ny flerfamiljshus samt identifiering av tekniska fel
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
indoor climate, apartments, questionnaire, measurements, occupants, window opening, technical deficiencies
host publication
NSB 2014 : 10th Nordic Symposium on Building Physics,15-19 June 2014 Lund, Sweden : Full Papers - 10th Nordic Symposium on Building Physics,15-19 June 2014 Lund, Sweden : Full Papers
series title
Rapport TVBH
issue
3061
pages
8 pages
publisher
Lunds universitet, Lunds tekniska högskola, Avdelningen för byggnadsfysik
conference name
10th Nordic Symposium in Building Physics
conference location
Lund, Sweden
conference dates
2014-06-15 - 2014-06-19
ISSN
0349-4950
ISBN
978-91-88722-53-9
language
English
LU publication?
yes
id
c9bac7a0-b649-4aab-9e0d-708305474855
alternative location
http://www.nsb2014.se/wordpress/wp-content/uploads/2014/07/Low_Energy_Buildings.pdf
date added to LUP
2017-10-17 11:12:33
date last changed
2018-11-21 21:35:32
@inproceedings{c9bac7a0-b649-4aab-9e0d-708305474855,
  abstract     = {{When new buildings are constructed the indoor climate for the first period may differ from the one after some years due to various factors, for example may the emissions from the building materials be higher, possibly affecting the air quality, and the balancing of the technical systems; the mechanical supply and exhaust system and heating may not be completely finished. The perceived indoor climate in new-multi family buildings, with the aim of low-energy use and good indoor climate, has been examined by questionnaires when the buildings were new. In this follow-up study the same questionnaire has been performed after some years. Measurements of the indoor climate and the performance of the technical systems have also been made in some apartments. The objectives are to compare the resident’s experience of indoor climate after some years of occupancy with when the buildings were new and to examine indoor climate and aspects influencing this after some years of occupancy. One objective being studied is the window opening in the apartments and factors related to this. No large difference in experience is seen after some years. A majority of the respondents open their windows during the heating season for rather long time periods and daily or almost every day. It was found that the resulting indoor climate is a complex interaction between the technical systems, the design of the building envelope and the behavior of the occupant. Several deficiencies in all this three areas have been identified and suggestions on possible improvements are included.}},
  author       = {{Nordquist, Birgitta and Fransson, Victor and Lindberg, Ola}},
  booktitle    = {{NSB 2014 : 10th Nordic Symposium on Building Physics,15-19 June 2014 Lund, Sweden : Full Papers}},
  isbn         = {{978-91-88722-53-9}},
  issn         = {{0349-4950}},
  keywords     = {{indoor climate; apartments; questionnaire; measurements; occupants; window opening; technical deficiencies}},
  language     = {{eng}},
  month        = {{06}},
  number       = {{3061}},
  pages        = {{846--853}},
  publisher    = {{Lunds universitet, Lunds tekniska högskola, Avdelningen för byggnadsfysik}},
  series       = {{Rapport TVBH}},
  title        = {{Perceived and measured indoor climate in new-family buildings including identifying technical deficiencies}},
  url          = {{http://www.nsb2014.se/wordpress/wp-content/uploads/2014/07/Low_Energy_Buildings.pdf}},
  year         = {{2014}},
}