Transcatheter aortic valve implantation in patients with small aortic annuli using a 20 mm balloon-expanding valve

Puri, Rishi ; Byrne, Jonathan ; Muller, Ralf ; Baumbach, Hardy ; Eltchaninoff, Helene ; Redwood, Simon ; Cheema, Asim ; Dubois, Christophe ; Ihlberg, Leo and Wijeysundera, Harindra C. , et al. (2017) In Heart 103. p.148-153
Abstract

Background While transcatheter aortic valve implantation (TAVI) is established for treating highoperative risk surgical aortic valve replacement candidates, until recently the smallest transcatheter heart valve (THV) measured 23 mm, posing greater risk for annular rupture and THV failure in patients with aortic stenosis (AS) with small aortic annuli (=20 mm). Objectives In the setting of a multicentre registry, we report on the safety, efficacy and early clinical outcomes of the SAPIEN XT 20 mm balloon-expanding THV. Results Among TAVI 55 recipients (n=30 for native AS, n=25 for a valve-in-valve procedure (V-in-V)), median age and Society of Thoracic Surgeons score were 85 (81 to 87) years and 7.8 (4.7 to 12.4)%, respectively. Mean and... (More)

Background While transcatheter aortic valve implantation (TAVI) is established for treating highoperative risk surgical aortic valve replacement candidates, until recently the smallest transcatheter heart valve (THV) measured 23 mm, posing greater risk for annular rupture and THV failure in patients with aortic stenosis (AS) with small aortic annuli (=20 mm). Objectives In the setting of a multicentre registry, we report on the safety, efficacy and early clinical outcomes of the SAPIEN XT 20 mm balloon-expanding THV. Results Among TAVI 55 recipients (n=30 for native AS, n=25 for a valve-in-valve procedure (V-in-V)), median age and Society of Thoracic Surgeons score were 85 (81 to 87) years and 7.8 (4.7 to 12.4)%, respectively. Mean and minimum annular diameters were 19±1 and 17±2 mm, respectively, in native patients with AS, and 17±1 mm (internal diameter) in V-in-V recipients. Successful device implantation rate was 96%, with no procedural-related death. Overall in-hospital-30-day death, stroke and major bleeding rates were 5%, 2% and 9%, respectively. In native AS TAVI recipients, mean transaortic gradient decreased from 54±20 to 12±5 mm Hg ( p<0.001), and from 45±17 to 24±8 mm Hg (p<0.001) in V-in-V recipients. Severe prosthesis-patient mismatch (PPM) rates were 10% and 48% in native AS and V-in-V TAVI recipients, respectively ( p=0.03). Post-TAVI, the rate of moderate aortic regurgitation was 7% and 0% in native AS and V-in-V TAVI recipients, respectively. Conclusions TAVI with the 20 mm SAPIEN XT THV appears safe and technically feasible, with acceptable short-term clinical outcomes and low rates of severe PPM in those with native AS.

(Less)
Please use this url to cite or link to this publication:
@article{f44c604d-8d24-4063-a033-66619d341420,
  abstract     = {{<p>Background While transcatheter aortic valve implantation (TAVI) is established for treating highoperative risk surgical aortic valve replacement candidates, until recently the smallest transcatheter heart valve (THV) measured 23 mm, posing greater risk for annular rupture and THV failure in patients with aortic stenosis (AS) with small aortic annuli (=20 mm). Objectives In the setting of a multicentre registry, we report on the safety, efficacy and early clinical outcomes of the SAPIEN XT 20 mm balloon-expanding THV. Results Among TAVI 55 recipients (n=30 for native AS, n=25 for a valve-in-valve procedure (V-in-V)), median age and Society of Thoracic Surgeons score were 85 (81 to 87) years and 7.8 (4.7 to 12.4)%, respectively. Mean and minimum annular diameters were 19±1 and 17±2 mm, respectively, in native patients with AS, and 17±1 mm (internal diameter) in V-in-V recipients. Successful device implantation rate was 96%, with no procedural-related death. Overall in-hospital-30-day death, stroke and major bleeding rates were 5%, 2% and 9%, respectively. In native AS TAVI recipients, mean transaortic gradient decreased from 54±20 to 12±5 mm Hg ( p&lt;0.001), and from 45±17 to 24±8 mm Hg (p&lt;0.001) in V-in-V recipients. Severe prosthesis-patient mismatch (PPM) rates were 10% and 48% in native AS and V-in-V TAVI recipients, respectively ( p=0.03). Post-TAVI, the rate of moderate aortic regurgitation was 7% and 0% in native AS and V-in-V TAVI recipients, respectively. Conclusions TAVI with the 20 mm SAPIEN XT THV appears safe and technically feasible, with acceptable short-term clinical outcomes and low rates of severe PPM in those with native AS.</p>}},
  author       = {{Puri, Rishi and Byrne, Jonathan and Muller, Ralf and Baumbach, Hardy and Eltchaninoff, Helene and Redwood, Simon and Cheema, Asim and Dubois, Christophe and Ihlberg, Leo and Wijeysundera, Harindra C. and Cerillo, Alfredo and Götberg, Matthias and Klaaborg, Kaj Erik and Pelletier, Marc and Blanco-Mata, Roberto and Edwards, Richard and Gandolfo, Caterina and Muir, Douglas and Meucci, Francesco and Sinning, Jan Malte and Stella, Pieter and Veulemans, Verena and Virtanen, Marko and Regueiro, Ander and Thoenes, Martin and Pibarot, Philippe and Pelletier-Beaumont, Emilie and Rodés-Cabau, Josep}},
  issn         = {{1355-6037}},
  keywords     = {{aortic valve implantation; Transcatheter}},
  language     = {{eng}},
  pages        = {{148--153}},
  publisher    = {{BMJ Publishing Group}},
  series       = {{Heart}},
  title        = {{Transcatheter aortic valve implantation in patients with small aortic annuli using a 20 mm balloon-expanding valve}},
  url          = {{http://dx.doi.org/10.1136/heartjnl-2016-309707}},
  doi          = {{10.1136/heartjnl-2016-309707}},
  volume       = {{103}},
  year         = {{2017}},
}