The Design of an Energy Efficient Highly Glazed Office Building

Blomsterberg, Åke LU (2006) EPIC 2006 AIVC 1. p.19-19
Abstract
Many modern office buildings have highly glazed facades. Their energy efficiency and indoor climate is, however, being questioned. Therefore, when a modern office building (new construction) with larger glazing areas was planned, an investigation was carried out to determine the possibilities to:

- efficiently use the increased access to daylight and thereby reduce the use of electricity for lighting and at the same time improve the visual comfort

- ensure good thermal comfort

- arrive at a reasonable total energy use, which is at the same level or preferably lower level than a traditional office building.



The work was done by a project group that supported the design team with advanced energy,... (More)
Many modern office buildings have highly glazed facades. Their energy efficiency and indoor climate is, however, being questioned. Therefore, when a modern office building (new construction) with larger glazing areas was planned, an investigation was carried out to determine the possibilities to:

- efficiently use the increased access to daylight and thereby reduce the use of electricity for lighting and at the same time improve the visual comfort

- ensure good thermal comfort

- arrive at a reasonable total energy use, which is at the same level or preferably lower level than a traditional office building.



The work was done by a project group that supported the design team with advanced energy, indoor climate and daylight simulations. Detailed performance specifications on energy use and indoor climate were worked out. The results show that the aims can be fulfilled if the following main requirements are fulfilled:

- The glazing area should not exceed 45 % of the façade area.

- The total solar transmittance of the glazing combined with solar shading must be lower than 0.1.

- The U-value of the windows must be lower than 1.1 W/m²K.



A double skin façade was chosen. An important conclusion is that coordination and cooperation throughout the building process is absolutely necessary. The building will be finished in 2007. (Less)
Please use this url to cite or link to this publication:
author
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
simulations., office building, double skin façade, glazed façade, design, Energy efficiency
host publication
[Host publication title missing]
volume
1
pages
19 - 19
publisher
Ecole Nationale des Travaux Publics de l'Etat, Lyon, France
conference name
EPIC 2006 AIVC
conference location
Lyon, France
conference dates
2006-11-20
language
English
LU publication?
yes
id
28a70d70-b1fc-467a-b04a-cf41e3305dfb (old id 1037944)
date added to LUP
2016-04-04 11:13:29
date last changed
2018-11-21 21:03:27
@inproceedings{28a70d70-b1fc-467a-b04a-cf41e3305dfb,
  abstract     = {{Many modern office buildings have highly glazed facades. Their energy efficiency and indoor climate is, however, being questioned. Therefore, when a modern office building (new construction) with larger glazing areas was planned, an investigation was carried out to determine the possibilities to:<br/><br>
-	efficiently use the increased access to daylight and thereby reduce the use of electricity for lighting and at the same time improve the visual comfort<br/><br>
-	ensure good thermal comfort<br/><br>
-	arrive at a reasonable total energy use, which is at the same level or preferably lower level than a traditional office building.<br/><br>
<br/><br>
The work was done by a project group that supported the design team with advanced energy, indoor climate and daylight simulations. Detailed performance specifications on energy use and indoor climate were worked out. The results show that the aims can be fulfilled if the following main requirements are fulfilled:<br/><br>
-	The glazing area should not exceed 45 % of the façade area. <br/><br>
-	The total solar transmittance of the glazing combined with solar shading must be lower than 0.1. <br/><br>
-	The U-value of the windows must be lower than 1.1 W/m²K.<br/><br>
<br/><br>
A double skin façade was chosen. An important conclusion is that coordination and cooperation throughout the building process is absolutely necessary. The building will be finished in 2007.}},
  author       = {{Blomsterberg, Åke}},
  booktitle    = {{[Host publication title missing]}},
  keywords     = {{simulations.; office building; double skin façade; glazed façade; design; Energy efficiency}},
  language     = {{eng}},
  pages        = {{19--19}},
  publisher    = {{Ecole Nationale des Travaux Publics de l'Etat, Lyon, France}},
  title        = {{The Design of an Energy Efficient Highly Glazed Office Building}},
  volume       = {{1}},
  year         = {{2006}},
}