Consistency analysis of torque measurements performed on a PMSM using dynamic testing

Hall, Sebastian LU ; Loayza Vargas, Yury LU ; Reinap, Avo LU and Alaküla, Mats LU orcid (2014) International Conference on Electrical Machines (ICEM), 2014 p.1529-1535
Abstract
Various applications need an electric machine that can provide a wide range of torque over a broad range of rotation speed and temperature. Dynamic testing, where the machine acceleration is compared to the deceleration slope, allows to scan through a wide scope of operation points with insignificant temperature rise. Therefore, the goal of this paper is to analyse the consistency of the rapid experimental evaluation method when comparing the torque derived from the electric input to the one derived from the mechanic output. The paper shows that the electromagnetic torque is estimated within 0.5% expected difference between the two ways of calculating the torque, depending on the selected operation points.
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
Machine testing, Permanent Magnet Machines
host publication
2014 International Conference on Electrical Machines (ICEM)
pages
1529 - 1535
publisher
IEEE - Institute of Electrical and Electronics Engineers Inc.
conference name
International Conference on Electrical Machines (ICEM), 2014
conference location
Berlin, Germany
conference dates
2014-09-02 - 2014-09-05
external identifiers
  • wos:000358567800227
  • scopus:84916222398
ISBN
9781479943883
DOI
10.1109/ICELMACH.2014.6960385
language
English
LU publication?
yes
id
9f3bdbfb-ad1b-46a0-8ae2-f844f34c72f9 (old id 7985062)
date added to LUP
2016-04-04 10:06:50
date last changed
2022-08-01 05:12:05
@inproceedings{9f3bdbfb-ad1b-46a0-8ae2-f844f34c72f9,
  abstract     = {{Various applications need an electric machine that can provide a wide range of torque over a broad range of rotation speed and temperature. Dynamic testing, where the machine acceleration is compared to the deceleration slope, allows to scan through a wide scope of operation points with insignificant temperature rise. Therefore, the goal of this paper is to analyse the consistency of the rapid experimental evaluation method when comparing the torque derived from the electric input to the one derived from the mechanic output. The paper shows that the electromagnetic torque is estimated within 0.5% expected difference between the two ways of calculating the torque, depending on the selected operation points.}},
  author       = {{Hall, Sebastian and Loayza Vargas, Yury and Reinap, Avo and Alaküla, Mats}},
  booktitle    = {{2014 International Conference on Electrical Machines (ICEM)}},
  isbn         = {{9781479943883}},
  keywords     = {{Machine testing; Permanent Magnet Machines}},
  language     = {{eng}},
  pages        = {{1529--1535}},
  publisher    = {{IEEE - Institute of Electrical and Electronics Engineers Inc.}},
  title        = {{Consistency analysis of torque measurements performed on a PMSM using dynamic testing}},
  url          = {{http://dx.doi.org/10.1109/ICELMACH.2014.6960385}},
  doi          = {{10.1109/ICELMACH.2014.6960385}},
  year         = {{2014}},
}