The objective of this work was to examine the evacuation process in a smokefilled environment. In a series of six experiments, eight subjects (in each experiment), were instructed to walk through a smoke filled room. The time and the smoke density were measured and the subjects
comments were collected. Geometry, lighting and smoke density was varied during the experiments. The smoke was of a non-irritating kind generated by a smoke generator. The work addresses both technical aspects as smoke density, lighting and walking speed as well as behavorial and orientational aspects. A model for estimating the orientational conditions was developed from the Visual Access concept first presented by J. Sime. The toxicological and physiological... (More)
The objective of this work was to examine the evacuation process in a smokefilled environment. In a series of six experiments, eight subjects (in each experiment), were instructed to walk through a smoke filled room. The time and the smoke density were measured and the subjects
comments were collected. Geometry, lighting and smoke density was varied during the experiments. The smoke was of a non-irritating kind generated by a smoke generator. The work addresses both technical aspects as smoke density, lighting and walking speed as well as behavorial and orientational aspects. A model for estimating the orientational conditions was developed from the Visual Access concept first presented by J. Sime. The toxicological and physiological aspect of the problem was not a key issue in this work but a summary of different methods of estimating physiological conditions is presented in an Appendix. (Swedish) (Less)
Please use this url to cite or link to this publication:
author
Gunnarsson, Henrik
supervisor
organization
year
type
M2 - Bachelor Degree
subject
keywords
orienteringsförutsättningar., förhållanden, kritiska, siktbarhet, gånghastighet, optisk täthet, rök, utrymning, rumsuppfattning, brand, Evakuering
publication/series
LUTVDG/TVBB--5118--SE
report number
5118
ISSN
1402-3504
language
Swedish
id
1767433
date added to LUP
2011-01-25 13:25:52
date last changed
2014-03-10 10:40:36
@misc{1767433,
  abstract     = {{The objective of this work was to examine the evacuation process in a smokefilled environment. In a series of six experiments, eight subjects (in each experiment), were instructed to walk through a smoke filled room. The time and the smoke density were measured and the subjects
comments were collected. Geometry, lighting and smoke density was varied during the experiments. The smoke was of a non-irritating kind generated by a smoke generator. The work addresses both technical aspects as smoke density, lighting and walking speed as well as behavorial and orientational aspects. A model for estimating the orientational conditions was developed from the Visual Access concept first presented by J. Sime. The toxicological and physiological aspect of the problem was not a key issue in this work but a summary of different methods of estimating physiological conditions is presented in an Appendix. (Swedish)}},
  author       = {{Gunnarsson, Henrik}},
  issn         = {{1402-3504}},
  language     = {{swe}},
  note         = {{Student Paper}},
  series       = {{LUTVDG/TVBB--5118--SE}},
  title        = {{Evakuering genom rök}},
  year         = {{2003}},
}