Advanced

Brandteknisk riskvärdering av Galleria Flanaden, Värnamo

Blomstrand, Jonatan; Karlsson, Robin; Olsén, Mari and Trägårdh, Frans (2010)
Division of Fire Safety Engineering
Fire Protection Engineering 3,5 years
Division of Risk Management and Societal Safety
Abstract
This report evaluates the personal safety issues in the event of fire in the Swedish shopping mall “Galleria Flanaden” in Värnamo. The building and its businesses’ compliance with Swedish fire safety legislation is verified (most importantly BBR 2008 and SFS 2003:778).
Weaknesses in personal safety (means of evacuation) in the event of fire are verified through an exhaustive on-site inspection and later scrutinized with the use of risk analysis, statistics, design fires, computer programs, hand calculations and other engineering tools.
It is concluded that the arcade is to be considered safe in the event of fire. However to fulfill Swedish fire safety legislation all personnel need to take a bigger part in day-to-day fire prevention with... (More)
This report evaluates the personal safety issues in the event of fire in the Swedish shopping mall “Galleria Flanaden” in Värnamo. The building and its businesses’ compliance with Swedish fire safety legislation is verified (most importantly BBR 2008 and SFS 2003:778).
Weaknesses in personal safety (means of evacuation) in the event of fire are verified through an exhaustive on-site inspection and later scrutinized with the use of risk analysis, statistics, design fires, computer programs, hand calculations and other engineering tools.
It is concluded that the arcade is to be considered safe in the event of fire. However to fulfill Swedish fire safety legislation all personnel need to take a bigger part in day-to-day fire prevention with systematic precautions. Also measures to improve emergency exits and their appropriate signposting need to be taken. (Less)
Please use this url to cite or link to this publication:
author
Blomstrand, Jonatan; Karlsson, Robin; Olsén, Mari and Trägårdh, Frans
supervisor
organization
year
type
L3 - Miscellaneous, Projetcs etc.
subject
keywords
utrymning, galleria, köpcentrum, detektion, kritiska förhållanden, personsäkerhet, brandskydd, brandteknisk utvärdering, känslighetsanalys, brandlarmssystem.
report number
9373
language
Swedish
id
1776276
date added to LUP
2011-02-02 08:42:41
date last changed
2014-03-10 10:40:37
@misc{1776276,
  abstract     = {This report evaluates the personal safety issues in the event of fire in the Swedish shopping mall “Galleria Flanaden” in Värnamo. The building and its businesses’ compliance with Swedish fire safety legislation is verified (most importantly BBR 2008 and SFS 2003:778).
Weaknesses in personal safety (means of evacuation) in the event of fire are verified through an exhaustive on-site inspection and later scrutinized with the use of risk analysis, statistics, design fires, computer programs, hand calculations and other engineering tools.
It is concluded that the arcade is to be considered safe in the event of fire. However to fulfill Swedish fire safety legislation all personnel need to take a bigger part in day-to-day fire prevention with systematic precautions. Also measures to improve emergency exits and their appropriate signposting need to be taken.},
  author       = {Blomstrand, Jonatan and Karlsson, Robin and Olsén, Mari and Trägårdh, Frans},
  keyword      = {utrymning,galleria,köpcentrum,detektion,kritiska förhållanden,personsäkerhet,brandskydd,brandteknisk utvärdering,känslighetsanalys,brandlarmssystem.},
  language     = {swe},
  note         = {Student Paper},
  title        = {Brandteknisk riskvärdering av Galleria Flanaden, Värnamo},
  year         = {2010},
}