Stepless fault injection for electrohydraulic actuator

Jönsson, Erik (2015)
Department of Automatic Control
Abstract
One of the cases for testing the BorgWarner GEN V clutch is to see if pump and motor malfunctions are detected by the software. Until now there have been a couple of fixed configurations testing clutches with different faults. The goal was to investigate if these configurations could be replaced by a normally functioning motor and pump connected to electrical circuits to mimic faulty clutches, which would ultimately lead to more flexibility during the testing. The work has been carried out at BorgWarner TTS in Landskrona.
Please use this url to cite or link to this publication:
author
Jönsson, Erik
supervisor
organization
year
type
H3 - Professional qualifications (4 Years - )
subject
ISSN
0280-5316
other publication id
ISRN LUTFD2/TFRT--5983--SE
language
English
id
7449037
date added to LUP
2015-07-03 09:47:05
date last changed
2015-07-03 09:47:05
@misc{7449037,
  abstract     = {{One of the cases for testing the BorgWarner GEN V clutch is to see if pump and motor malfunctions are detected by the software. Until now there have been a couple of fixed configurations testing clutches with different faults. The goal was to investigate if these configurations could be replaced by a normally functioning motor and pump connected to electrical circuits to mimic faulty clutches, which would ultimately lead to more flexibility during the testing. The work has been carried out at BorgWarner TTS in Landskrona.}},
  author       = {{Jönsson, Erik}},
  issn         = {{0280-5316}},
  language     = {{eng}},
  note         = {{Student Paper}},
  title        = {{Stepless fault injection for electrohydraulic actuator}},
  year         = {{2015}},
}