Halmstad Arena - En brandteknisk riskvärdering av hall D
(2016) VBR054 20161Division of Fire Safety Engineering
- Abstract
- This work evaluates the personal safety in case of a fire in Halmstad Arena hall D, an ice rink which is also used for exhibitions during the summer. Simulations and calculations were performed on possible design fires based on information given by an on-site visit and given design drawings. Solutions were discussed and conclusions drawn to increase the maximum number of people allowed in the building, opening up for the possibility of arranging larger expos and exhibitions in the premises.
Three design fires were considered more plausible and with bigger consequences. These are fire in ice resurfacers, fire in expo showcase and fire in storage room.
The results from this work show that 1200 people can perform a safe evacuation... (More) - This work evaluates the personal safety in case of a fire in Halmstad Arena hall D, an ice rink which is also used for exhibitions during the summer. Simulations and calculations were performed on possible design fires based on information given by an on-site visit and given design drawings. Solutions were discussed and conclusions drawn to increase the maximum number of people allowed in the building, opening up for the possibility of arranging larger expos and exhibitions in the premises.
Three design fires were considered more plausible and with bigger consequences. These are fire in ice resurfacers, fire in expo showcase and fire in storage room.
The results from this work show that 1200 people can perform a safe evacuation without
implementing any additional structural fire safety measures, though subject to some minor
measures such as guiding markings on the exhibition floor. (Less)
Please use this url to cite or link to this publication:
http://lup.lub.lu.se/student-papers/record/8876984
- author
- Andersson, Johanna LU ; Edman, Elin LU ; Nilsson, Erik LU and Ragnar, Hampus
- supervisor
- organization
- alternative title
- Halmstad Arena - A Fire Safety Evaluation of Hall D
- course
- VBR054 20161
- year
- 2016
- type
- L3 - Miscellaneous, Projetcs etc.
- subject
- keywords
- Idrottsarena, Halmstad Arena, brandteknisk riskvärdering, FDS, Pathfinder, Sports arena, fire safety evaluation
- report number
- 9488
- language
- Swedish
- id
- 8876984
- date added to LUP
- 2016-06-21 16:27:26
- date last changed
- 2016-06-21 16:27:26
@misc{8876984, abstract = {{This work evaluates the personal safety in case of a fire in Halmstad Arena hall D, an ice rink which is also used for exhibitions during the summer. Simulations and calculations were performed on possible design fires based on information given by an on-site visit and given design drawings. Solutions were discussed and conclusions drawn to increase the maximum number of people allowed in the building, opening up for the possibility of arranging larger expos and exhibitions in the premises. Three design fires were considered more plausible and with bigger consequences. These are fire in ice resurfacers, fire in expo showcase and fire in storage room. The results from this work show that 1200 people can perform a safe evacuation without implementing any additional structural fire safety measures, though subject to some minor measures such as guiding markings on the exhibition floor.}}, author = {{Andersson, Johanna and Edman, Elin and Nilsson, Erik and Ragnar, Hampus}}, language = {{swe}}, note = {{Student Paper}}, title = {{Halmstad Arena - En brandteknisk riskvärdering av hall D}}, year = {{2016}}, }