The objective of this study is to increase knowledge in Sweden, concerning elevator use in fire situations. This includes designing hardware and human strategies necessary for people and fire department in their use of fire elevators.

This report addresses an important aspect in making the elevator safe to use during a fire. By using a pressurisation concept, smoke is prevented from reaching the fire elevator and its lobby. Another important aspect is human behaviour and interaction with the fire elevator, which also is addressed in this report.

The use of fire elevators implies a change in risk compared to traditional stairwell evacuation. This report contains a probabilistic comparison between stairwell and fire elevator evacuation.
Please use this url to cite or link to this publication:
author
Ardenmark, Joakim
supervisor
organization
year
type
M2 - Bachelor Degree
subject
keywords
pressurisation, evacuation, elevator, stairwell, Fire elevator, BBR, High rise building, tall building, fault-tree analysis, human behaviour
publication/series
LUTVDG/TVBB-5041-SE
report number
5041
ISSN
1402-3504
language
Swedish
id
1767188
date added to LUP
2011-01-26 10:46:47
date last changed
2014-03-10 10:40:36
@misc{1767188,
  abstract     = {{The objective of this study is to increase knowledge in Sweden, concerning elevator use in fire situations. This includes designing hardware and human strategies necessary for people and fire department in their use of fire elevators.

This report addresses an important aspect in making the elevator safe to use during a fire. By using a pressurisation concept, smoke is prevented from reaching the fire elevator and its lobby. Another important aspect is human behaviour and interaction with the fire elevator, which also is addressed in this report.

The use of fire elevators implies a change in risk compared to traditional stairwell evacuation. This report contains a probabilistic comparison between stairwell and fire elevator evacuation.}},