Energikloka hus i Järinge - energiteknisk uppföljning
(2009)Civil Engineering - Architecture (BSc)
- Abstract
- Energy-wise houses in Järinge - technical follow-up The company JM built energy-efficient houses in Tensta in Stockholm. They have built a total of 16 houses divided into two parts of A-houses and B-houses. The buildings are an attempt by JM to minimize energy-use of the buildings without affecting the comfort and living standards. The project aims to examine the data for the 16 houses on the basis of data and produce a report showing how the buildings worked through a technical perspective. JM approximates that the purchased energy will not be higher than 95 kWh/m2 per year. Data-reading has been done every hour. After the period, we received data in two different Excel files. We have then created images of data in a matlab program. Our... (More)
- Energy-wise houses in Järinge - technical follow-up The company JM built energy-efficient houses in Tensta in Stockholm. They have built a total of 16 houses divided into two parts of A-houses and B-houses. The buildings are an attempt by JM to minimize energy-use of the buildings without affecting the comfort and living standards. The project aims to examine the data for the 16 houses on the basis of data and produce a report showing how the buildings worked through a technical perspective. JM approximates that the purchased energy will not be higher than 95 kWh/m2 per year. Data-reading has been done every hour. After the period, we received data in two different Excel files. We have then created images of data in a matlab program. Our results for the first quarter of 2008 demonstrated that A-houses have an average of about 27 kWh/m² excluding domestic electricity and about 38 kh/m² including domestic electricity. The climate during winter requires a larger indoor heating because of the cold climate outdoors, and therefore the energy consumed in that period will be greater. If we see our results as a quarter of the total, the houses are likely to meet the requirement. (Less)
Please use this url to cite or link to this publication:
http://lup.lub.lu.se/student-papers/record/1352897
- author
- Alvén, Nicholas and Softic, Zlatan
- organization
- year
- 2009
- type
- M2 - Bachelor Degree
- subject
- keywords
- energikloka hus, energianvändning, Building construction, Byggnadsteknik
- language
- Swedish
- id
- 1352897
- date added to LUP
- 2009-03-12 00:00:00
- date last changed
- 2018-10-18 09:55:36
@misc{1352897, abstract = {{Energy-wise houses in Järinge - technical follow-up The company JM built energy-efficient houses in Tensta in Stockholm. They have built a total of 16 houses divided into two parts of A-houses and B-houses. The buildings are an attempt by JM to minimize energy-use of the buildings without affecting the comfort and living standards. The project aims to examine the data for the 16 houses on the basis of data and produce a report showing how the buildings worked through a technical perspective. JM approximates that the purchased energy will not be higher than 95 kWh/m2 per year. Data-reading has been done every hour. After the period, we received data in two different Excel files. We have then created images of data in a matlab program. Our results for the first quarter of 2008 demonstrated that A-houses have an average of about 27 kWh/m² excluding domestic electricity and about 38 kh/m² including domestic electricity. The climate during winter requires a larger indoor heating because of the cold climate outdoors, and therefore the energy consumed in that period will be greater. If we see our results as a quarter of the total, the houses are likely to meet the requirement.}}, author = {{Alvén, Nicholas and Softic, Zlatan}}, language = {{swe}}, note = {{Student Paper}}, title = {{Energikloka hus i Järinge - energiteknisk uppföljning}}, year = {{2009}}, }