Skip to main content

LUP Student Papers

LUND UNIVERSITY LIBRARIES

Brandteknisk riskvärdering av High Chaparral

Jacobsson, Joel ; Nilsson, Magnus ; Svensson, Henric and Öberg, Richard (2003)
Division of Fire Safety Engineering
Fire Protection Engineering 3,5 years
Division of Risk Management and Societal Safety
Abstract
This report has been done to evaluate the fire safety in saloon Cheyenne with staff area at High Chaparral. It has been a goal in this report to be able to give a specific number of people to each of the departments and this has been done. Different safety systems have been added to the building during simulations and the requirement of the systems has been investigated. The safety systems have been tested in three different scenarios. The scenarios have been picked for different reasons but keywords have been probability and consequence.
The programs used for this assignment are Argos, Simulex and FDS. Argos is a two zone model. FDS is a CFD model and Simulex is an egress program.
Please use this url to cite or link to this publication:
author
Jacobsson, Joel ; Nilsson, Magnus ; Svensson, Henric and Öberg, Richard
supervisor
organization
year
type
L3 - Miscellaneous, Projetcs etc.
subject
keywords
High Chaparral, Utrymning, Brandsäkerhet, Kritisk tid, Brand modulering, Argos, FDS, Simulex, Saloon.
report number
9206
language
Swedish
id
1775969
date added to LUP
2011-02-02 10:25:41
date last changed
2014-03-10 10:40:37
@misc{1775969,
  abstract     = {{This report has been done to evaluate the fire safety in saloon Cheyenne with staff area at High Chaparral. It has been a goal in this report to be able to give a specific number of people to each of the departments and this has been done. Different safety systems have been added to the building during simulations and the requirement of the systems has been investigated. The safety systems have been tested in three different scenarios. The scenarios have been picked for different reasons but keywords have been probability and consequence.
The programs used for this assignment are Argos, Simulex and FDS. Argos is a two zone model. FDS is a CFD model and Simulex is an egress program.}},
  author       = {{Jacobsson, Joel and Nilsson, Magnus and Svensson, Henric and Öberg, Richard}},
  language     = {{swe}},
  note         = {{Student Paper}},
  title        = {{Brandteknisk riskvärdering av High Chaparral}},
  year         = {{2003}},
}