Skip to main content

LUP Student Papers

LUND UNIVERSITY LIBRARIES

Developing a prototype using IMUs to do 24 hours measurement of knee joint mobility in children with Cerebral Palsy

Ahmed, Anza LU (2019) BMEM01 20192
Department of Biomedical Engineering
Abstract
Cerebral Palsy (CP) is a disorder of movement that is caused before, during or soon after birth. CP affects movement and co-ordination caused by lack of muscle control by the brain [1], [2]. Stiff muscles, weak muscles, tremors and seizures as well as difficulties with swallowing are examples of symptoms in children with CP. Every year there are approximately 200 children born in Sweden that are affected by CP [3].

Children affected by CP must visit physicians or physiotherapists for an evaluation check up on their joints. Physicians use a goniometer to study the knee flexion/extension angle thus providing a plan for rehabilitation treatments. A challenge for the physiotherapists is that they are unable to measure the knee joint... (More)
Cerebral Palsy (CP) is a disorder of movement that is caused before, during or soon after birth. CP affects movement and co-ordination caused by lack of muscle control by the brain [1], [2]. Stiff muscles, weak muscles, tremors and seizures as well as difficulties with swallowing are examples of symptoms in children with CP. Every year there are approximately 200 children born in Sweden that are affected by CP [3].

Children affected by CP must visit physicians or physiotherapists for an evaluation check up on their joints. Physicians use a goniometer to study the knee flexion/extension angle thus providing a plan for rehabilitation treatments. A challenge for the physiotherapists is that they are unable to measure the knee joint movement of children with CP for a longer period. There is a lack of research in the area of CP combined with long term measurement devices. This thesis project had a main purpose to create a prototype that was able to measure the knee joint angle in children with CP in their normal environment, for 24 hours.

Two BNO055 inertial measurement units (IMUs) were used to obtain the knee joint angle by using quaternions, which are a number system in four dimensions. The final prototype was tested on a robot and human subject. The results concluded that BNO055 is a good IMU when the measurements are performed for a short time with slow or linear movements. For longer periods, however, the sensors lose their calibration and provide drifted results, hence it is not suited for doing measurements for 24 hours. Another upgraded and high cost sensor BNO080 was then replaced that provided more accurate results for knee joint angles over a longer period of motion. BNO080 also provided short drifting results over time, but not as bad as BNO055. Due to its many operational modes, it might be possible to overcome drifting errors.

It was possible to develop a device for knee joint measurements with promising results for shorter periods, however, to continuously measure data for 24 hours on nonlinear human knee motions, a strong IMU with good autocalibration techniques is needed, and this is something that needs to be tested and studied further. (Less)
Popular Abstract
How modern technology to measure the knee joint mobility might help children with Cerebral Palsy (CP)

CP is a disorder of movement that affects co-ordination caused by lack of muscle control by the brain. CP patients have knee joint disorder such as stiff-knee gait and flexion and extension deformities. There is a lack of research on measuring the knee joint angle for a longer period on children with CP using modern technology. This could help physicians or physiotherapists to provide better rehabilitation treatments accordingly to every child’s needs. Using IMU (Inertial measurement unit) might be a solution for this.
Please use this url to cite or link to this publication:
author
Ahmed, Anza LU
supervisor
organization
course
BMEM01 20192
year
type
H2 - Master's Degree (Two Years)
subject
keywords
IMU, Biomedical engineering, sensors, cerebral palsy, CP, BNO055, BNO080, knee joint, Arduino, electrical engineering
language
English
additional info
2019-13
id
8996696
date added to LUP
2019-11-04 10:12:38
date last changed
2019-11-04 10:12:38
@misc{8996696,
  abstract     = {{Cerebral Palsy (CP) is a disorder of movement that is caused before, during or soon after birth. CP affects movement and co-ordination caused by lack of muscle control by the brain [1], [2]. Stiff muscles, weak muscles, tremors and seizures as well as difficulties with swallowing are examples of symptoms in children with CP. Every year there are approximately 200 children born in Sweden that are affected by CP [3]. 

Children affected by CP must visit physicians or physiotherapists for an evaluation check up on their joints. Physicians use a goniometer to study the knee flexion/extension angle thus providing a plan for rehabilitation treatments. A challenge for the physiotherapists is that they are unable to measure the knee joint movement of children with CP for a longer period. There is a lack of research in the area of CP combined with long term measurement devices. This thesis project had a main purpose to create a prototype that was able to measure the knee joint angle in children with CP in their normal environment, for 24 hours.
 
Two BNO055 inertial measurement units (IMUs) were used to obtain the knee joint angle by using quaternions, which are a number system in four dimensions. The final prototype was tested on a robot and human subject. The results concluded that BNO055 is a good IMU when the measurements are performed for a short time with slow or linear movements. For longer periods, however, the sensors lose their calibration and provide drifted results, hence it is not suited for doing measurements for 24 hours. Another upgraded and high cost sensor BNO080 was then replaced that provided more accurate results for knee joint angles over a longer period of motion. BNO080 also provided short drifting results over time, but not as bad as BNO055. Due to its many operational modes, it might be possible to overcome drifting errors. 

It was possible to develop a device for knee joint measurements with promising results for shorter periods, however, to continuously measure data for 24 hours on nonlinear human knee motions, a strong IMU with good autocalibration techniques is needed, and this is something that needs to be tested and studied further.}},
  author       = {{Ahmed, Anza}},
  language     = {{eng}},
  note         = {{Student Paper}},
  title        = {{Developing a prototype using IMUs to do 24 hours measurement of knee joint mobility in children with Cerebral Palsy}},
  year         = {{2019}},
}