Kritiska fukt - och temperatur - r örelser i putsade skivfasader
(2013)Civil Engineering (M.Sc.Eng.)
Division of Structural Engineering
- Abstract
- In general the facade should be aesthetically appealing, but also its practical functions from a moisture control point of view are of importance. Two step sealed facades, where the outer part consists of a cementboard and plaster, are becoming increasingly common in the selection of type of facade. A specific tvåstegstätad facade that is becoming more established on the market is the facade, where the outer part is made of cementbased board, Aquapanel, and a top layer of plaster. Knowledge of this design is limited to its behavior when subjected to humidity and temperature variations over a longer period of time. What has not been fully studied is the behavior of the facade during shorter more intense periods. Therefore, the main task of... (More)
- In general the facade should be aesthetically appealing, but also its practical functions from a moisture control point of view are of importance. Two step sealed facades, where the outer part consists of a cementboard and plaster, are becoming increasingly common in the selection of type of facade. A specific tvåstegstätad facade that is becoming more established on the market is the facade, where the outer part is made of cementbased board, Aquapanel, and a top layer of plaster. Knowledge of this design is limited to its behavior when subjected to humidity and temperature variations over a longer period of time. What has not been fully studied is the behavior of the facade during shorter more intense periods. Therefore, the main task of the report was to identify the critical days and its influence on the Aquapanel and plaster. (Less)
Please use this url to cite or link to this publication:
http://lup.lub.lu.se/student-papers/record/4461427
- author
- Buza, Almedin and Ladan, Vedran
- supervisor
- organization
- year
- 2013
- type
- H3 - Professional qualifications (4 Years - )
- subject
- report number
- TVBK-5228
- ISSN
- 0349-4969
- language
- Swedish
- id
- 4461427
- date added to LUP
- 2014-06-12 15:33:37
- date last changed
- 2014-06-12 15:33:37
@misc{4461427, abstract = {{In general the facade should be aesthetically appealing, but also its practical functions from a moisture control point of view are of importance. Two step sealed facades, where the outer part consists of a cementboard and plaster, are becoming increasingly common in the selection of type of facade. A specific tvåstegstätad facade that is becoming more established on the market is the facade, where the outer part is made of cementbased board, Aquapanel, and a top layer of plaster. Knowledge of this design is limited to its behavior when subjected to humidity and temperature variations over a longer period of time. What has not been fully studied is the behavior of the facade during shorter more intense periods. Therefore, the main task of the report was to identify the critical days and its influence on the Aquapanel and plaster.}}, author = {{Buza, Almedin and Ladan, Vedran}}, issn = {{0349-4969}}, language = {{swe}}, note = {{Student Paper}}, title = {{Kritiska fukt - och temperatur - r örelser i putsade skivfasader}}, year = {{2013}}, }