In-line Phase-contrast Tomography using Betatron X-rays Produced by a Laser-Plasma Accelerator

Svendsen, Kristoffer LU (2017) PHYM01 20171
Atomic Physics
Department of Physics
Abstract
X-ray phase-contrast imaging is a powerful technique that allows great resolving power for low absorbing samples, such as biological tissue. This method relies on measuring the phase shift induced by the sample instead of the absorption traditional radiography relies on. This phase shift is measured as an intensity modulation at the detector and by using various algorithms one can obtain information about the sample. This technique can be combined with standard tomography to get a full 3 dimensional reconstruction of the sample.

Phase-contrast imaging requires a large transversal coherence, requiring a very small x-ray source size, limiting the choice of source to either microfocus x-ray tubes or a synchrotron facility. Microfocus... (More)
X-ray phase-contrast imaging is a powerful technique that allows great resolving power for low absorbing samples, such as biological tissue. This method relies on measuring the phase shift induced by the sample instead of the absorption traditional radiography relies on. This phase shift is measured as an intensity modulation at the detector and by using various algorithms one can obtain information about the sample. This technique can be combined with standard tomography to get a full 3 dimensional reconstruction of the sample.

Phase-contrast imaging requires a large transversal coherence, requiring a very small x-ray source size, limiting the choice of source to either microfocus x-ray tubes or a synchrotron facility. Microfocus x-ray tubes have very small source sizes but very limited flux, resulting in long exposure times while the beam time at a synchrotron facility is very expensive and limited. Laser based plasma acceleration could prove to be an alternative source for this purpose and this thesis dwells on this possibility, the source size is very small and the brilliance can be compared with that of a synchrotron. The generated x-ray pulses are also very short, on the femtosecond scale, reducing the exposure time needed for a well resolved image, resulting in faster data acquisition and holds promise for time resolved imaging. During the work presented in this thesis a source size measurement was conducted, showing a source size less than 2.5 microns, well suited for phase-contrast imaging. Experiments were carried out using low-absorbing samples such as mylar wires and a few different biological samples in the form of insects. The acquired phase-contrast images were used to calculate the projected thickness and by doing a tomography scan a full 3D reconstruction was created. In conclusion, this thesis shows laser based plasma accelerators to be a good source for phase-contrast imaging in low absorbing materials. Further, it proved to be able to resolve very small details, on the order of tens of microns and could possibly be improved further. (Less)
Popular Abstract
Since the discovery of x-rays they have allowed us to see inside objects without the need to destroy, cut or damage them. This has been useful in many ways, foremost in the field of medicine where you can take images of the skeleton or other parts without the need of surgery. This works on the principle that x-rays penetrate objects more easily than visible light and it can penetrate deeper in skin for example. Denser objects are still harder to penetrate however, such as bone, and this leaves a shadow as fewer x-rays penetrate it. This also limits the technique in a way because it only allows you to see objects that are very dense compared to the surroundings, a bone surrounded by tissue for example. As such, it is not possible to see,... (More)
Since the discovery of x-rays they have allowed us to see inside objects without the need to destroy, cut or damage them. This has been useful in many ways, foremost in the field of medicine where you can take images of the skeleton or other parts without the need of surgery. This works on the principle that x-rays penetrate objects more easily than visible light and it can penetrate deeper in skin for example. Denser objects are still harder to penetrate however, such as bone, and this leaves a shadow as fewer x-rays penetrate it. This also limits the technique in a way because it only allows you to see objects that are very dense compared to the surroundings, a bone surrounded by tissue for example. As such, it is not possible to see, say a tendon surrounded by tissue as they absorb about equal amounts of x-rays. This is where the technique of phase-contrast imaging comes in. It does not rely on how much x-rays the object absorbs, instead it relies on the difference in refractive index. As an example, say you have a piece of glass in water, both the glass and the water absorb about the same amount of x-rays so the glass would be hard to distinguish. But the refractive index of water compared to that of glass is quite different and taking phase-contrast images you would clearly be able to see the difference. This means that this technique has many useful applications but the problem is that it requires the source of the x-rays to be incredibly small, a few micrometers, and at the same time you need a lot of x-rays. This means that you either have to go to a synchrotron, which is very expensive and not always available, or use a microfocus x-ray tube that produces less x-rays.

In recent years a new type of particle accelerator has begun to catch the interest of a lot of researchers, called laser wakefield acceleration (LWFA). This uses a plasma to accelerate particles, usually electrons, over a very short distance. As a comparison, the linear accelerator at the MAX IV Laboratory accelerates electrons over 300 m, LWFA can reach the same energy over a distance of about 9 cm. The electrons emit x-rays when accelerated and this generates a very small x-ray source and was determined during this thesis to be 2.5 micrometers, which makes it suitable for phase-contrast imaging.

By rotating the object, taking images at different angles, one can reconstruct the full object in 3D even though the images are only 2D. Combining this with phase-contrast imaging makes it possible to create 3D images of small objects with little absorption. These 3D models can then be analyzed, such as cutting through different parts, rotating them, looking on the inside etc and this is demonstrated using a small fly in this thesis. Developing LWFA x-ray sources further could one day allow for phase-contrast imaging of for example blood vessels or tendons at medical facilities with very short exposure times compared to microfocus x-ray tubes. It would allow imaging of different low absorbing samples that usually require a synchrotron at much smaller and cheaper facilities. (Less)
Please use this url to cite or link to this publication:
author
Svendsen, Kristoffer LU
supervisor
organization
course
PHYM01 20171
year
type
H2 - Master's Degree (Two Years)
subject
keywords
source size, x-ray, in-line, phase-contrast, phase contrast, LWFA, laser wakefield acceleration, tomography, diffraction, diffraction simulation, laser-plasma acceleration
report number
536
language
English
id
8916566
date added to LUP
2017-06-16 15:28:37
date last changed
2017-06-16 15:28:37
@misc{8916566,
  abstract     = {{X-ray phase-contrast imaging is a powerful technique that allows great resolving power for low absorbing samples, such as biological tissue. This method relies on measuring the phase shift induced by the sample instead of the absorption traditional radiography relies on. This phase shift is measured as an intensity modulation at the detector and by using various algorithms one can obtain information about the sample. This technique can be combined with standard tomography to get a full 3 dimensional reconstruction of the sample. 

Phase-contrast imaging requires a large transversal coherence, requiring a very small x-ray source size, limiting the choice of source to either microfocus x-ray tubes or a synchrotron facility. Microfocus x-ray tubes have very small source sizes but very limited flux, resulting in long exposure times while the beam time at a synchrotron facility is very expensive and limited. Laser based plasma acceleration could prove to be an alternative source for this purpose and this thesis dwells on this possibility, the source size is very small and the brilliance can be compared with that of a synchrotron. The generated x-ray pulses are also very short, on the femtosecond scale, reducing the exposure time needed for a well resolved image, resulting in faster data acquisition and holds promise for time resolved imaging. During the work presented in this thesis a source size measurement was conducted, showing a source size less than 2.5 microns, well suited for phase-contrast imaging. Experiments were carried out using low-absorbing samples such as mylar wires and a few different biological samples in the form of insects. The acquired phase-contrast images were used to calculate the projected thickness and by doing a tomography scan a full 3D reconstruction was created. In conclusion, this thesis shows laser based plasma accelerators to be a good source for phase-contrast imaging in low absorbing materials. Further, it proved to be able to resolve very small details, on the order of tens of microns and could possibly be improved further.}},
  author       = {{Svendsen, Kristoffer}},
  language     = {{eng}},
  note         = {{Student Paper}},
  title        = {{In-line Phase-contrast Tomography using Betatron X-rays Produced by a Laser-Plasma Accelerator}},
  year         = {{2017}},
}