Can grating interferometry-based mammography discriminate benign from malignant microcalcifications in fresh biopsy samples?
(2020) In European Journal of Radiology 129.- Abstract
- Purpose
In addition to absorption imaging, grating interferometry-based mammography (GIM) is capable of detecting differential-phase and scattering signals. In particular, the scattering signal can enable a quantifiable characterization of breast lesions. The purpose of this study was to determine if suspicious microcalcifications associated with benign or malignant lesions can be discriminated based on their absorption and scattering properties.
Materials and Methods
In this prospective, ethically approved study, 62 patients (mean age 60 y, range 39–89) with suspicious microcalcifications, who underwent stereotactic biopsies, were included. Biopsies were measured with an experimental GIM device and the ratios of the scattering... (More) - Purpose
In addition to absorption imaging, grating interferometry-based mammography (GIM) is capable of detecting differential-phase and scattering signals. In particular, the scattering signal can enable a quantifiable characterization of breast lesions. The purpose of this study was to determine if suspicious microcalcifications associated with benign or malignant lesions can be discriminated based on their absorption and scattering properties.
Materials and Methods
In this prospective, ethically approved study, 62 patients (mean age 60 y, range 39–89) with suspicious microcalcifications, who underwent stereotactic biopsies, were included. Biopsies were measured with an experimental GIM device and the ratios of the scattering and absorption signal (R-value) for microcalcifications were calculated. The mean R-values for benign and malignant lesions associated with microcalcifications were compared with the final histopathological diagnosis using a t-test.
Results
Twenty of the 62 participants had microcalcifications associated with malignancy. Comparing the two largest histopathological sub-groups of fibrosis (n = 23) vs. ductal carcinoma in situ (n = 15) resulted in an average R-value of 4.08 for benign and 2.80 for malignant lesions; p = 0.07. All microcalcifications associated with malignancy had an R-value below 4.71. Excluding microcalcifications with an R-value above this threshold would result in an 11 % reduction of false positives.
Conclusion
The novel GIM modality has the potential to non-invasively characterize microcalcifications and might aid in the discrimination of benign from malignant lesions in fresh biopsy samples. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/043aa44d-fad2-46c5-a2fd-5ea8b618479c
- author
- Forte, Serafino ; Wang, Zhentian ; Arboleda, Carolina ; Lång, Kristina LU ; Singer, Gad ; Kubik-Huch, Rahel Antonia and Stampanoni, Marco
- publishing date
- 2020-05-16
- type
- Contribution to journal
- publication status
- published
- in
- European Journal of Radiology
- volume
- 129
- article number
- 109077
- publisher
- Elsevier
- external identifiers
-
- scopus:85084863062
- pmid:32446126
- ISSN
- 1872-7727
- DOI
- 10.1016/j.ejrad.2020.109077
- language
- English
- LU publication?
- no
- id
- 043aa44d-fad2-46c5-a2fd-5ea8b618479c
- date added to LUP
- 2020-06-29 20:40:59
- date last changed
- 2022-04-18 23:15:16
@article{043aa44d-fad2-46c5-a2fd-5ea8b618479c, abstract = {{Purpose<br/>In addition to absorption imaging, grating interferometry-based mammography (GIM) is capable of detecting differential-phase and scattering signals. In particular, the scattering signal can enable a quantifiable characterization of breast lesions. The purpose of this study was to determine if suspicious microcalcifications associated with benign or malignant lesions can be discriminated based on their absorption and scattering properties.<br/>Materials and Methods<br/>In this prospective, ethically approved study, 62 patients (mean age 60 y, range 39–89) with suspicious microcalcifications, who underwent stereotactic biopsies, were included. Biopsies were measured with an experimental GIM device and the ratios of the scattering and absorption signal (R-value) for microcalcifications were calculated. The mean R-values for benign and malignant lesions associated with microcalcifications were compared with the final histopathological diagnosis using a t-test.<br/>Results<br/>Twenty of the 62 participants had microcalcifications associated with malignancy. Comparing the two largest histopathological sub-groups of fibrosis (n = 23) vs. ductal carcinoma in situ (n = 15) resulted in an average R-value of 4.08 for benign and 2.80 for malignant lesions; p = 0.07. All microcalcifications associated with malignancy had an R-value below 4.71. Excluding microcalcifications with an R-value above this threshold would result in an 11 % reduction of false positives.<br/>Conclusion<br/>The novel GIM modality has the potential to non-invasively characterize microcalcifications and might aid in the discrimination of benign from malignant lesions in fresh biopsy samples.}}, author = {{Forte, Serafino and Wang, Zhentian and Arboleda, Carolina and Lång, Kristina and Singer, Gad and Kubik-Huch, Rahel Antonia and Stampanoni, Marco}}, issn = {{1872-7727}}, language = {{eng}}, month = {{05}}, publisher = {{Elsevier}}, series = {{European Journal of Radiology}}, title = {{Can grating interferometry-based mammography discriminate benign from malignant microcalcifications in fresh biopsy samples?}}, url = {{http://dx.doi.org/10.1016/j.ejrad.2020.109077}}, doi = {{10.1016/j.ejrad.2020.109077}}, volume = {{129}}, year = {{2020}}, }