Emission and dose characterization of the 1 kHz repetition rate high-Z metal K α source driven by 20 mJ femtosecond pulses
(2019) In Applied Physics B: Lasers and Optics 125(3).- Abstract
We present the hard X-ray generation of K
α
lines in high-Z elements – platinum and tungsten – targets using the kHz repetition rate TW-class 850 nm, 10 fs laser pulses. The estimated Pt and W Kα1 X-ray photon flux from the recorded spectrum was 1.3 × 10
7
and 1.4 × 10
7
photons/s,... (More)
(Less)
We present the hard X-ray generation of K
α
lines in high-Z elements – platinum and tungsten – targets using the kHz repetition rate TW-class 850 nm, 10 fs laser pulses. The estimated Pt and W Kα1 X-ray photon flux from the recorded spectrum was 1.3 × 10
7
and 1.4 × 10
7
photons/s, respectively, in 2π solid angle. The calculated values of the photon conversion efficiency were 1.3 × 10
- 8
for Pt Kα1 and 9 × 10
- 9
for W Kα1. The additional experimental bremsstrahlung-induced dose measurements and modeling were performed. The correspondence between experimental and modeling data for the dose evaluation was found. The dose rate up to 25 μ Sv/h was measured on the top of the X-ray generation chamber.
- author
- Reklaitis, Jonas ; Barkauskas, Vytenis LU ; Plukis, Artūras ; Kovalevskij, Vitalij ; Gaspariūnas, Mindaugas ; Germanas, Darius ; Garankin, Jevgenij ; Stanislauskas, Tomas ; Jasiūnas, Kęstutis and Remeikis, Vidmantas
- publishing date
- 2019-03-01
- type
- Contribution to journal
- publication status
- published
- in
- Applied Physics B: Lasers and Optics
- volume
- 125
- issue
- 3
- article number
- 41
- publisher
- Springer
- external identifiers
-
- scopus:85061505123
- ISSN
- 0946-2171
- DOI
- 10.1007/s00340-019-7155-6
- language
- English
- LU publication?
- no
- id
- 050f6bfc-f3ea-470c-a97f-a1254fda2999
- date added to LUP
- 2019-05-20 10:35:12
- date last changed
- 2025-10-14 08:54:46
@article{050f6bfc-f3ea-470c-a97f-a1254fda2999,
abstract = {{<p><br>
We present the hard X-ray generation of K <br>
<sub>α</sub><br>
lines in high-Z elements – platinum and tungsten – targets using the kHz repetition rate TW-class 850 nm, 10 fs laser pulses. The estimated Pt and W Kα1 X-ray photon flux from the recorded spectrum was 1.3 × 10 <br>
<sup>7</sup><br>
and 1.4 × 10 <br>
<sup>7</sup><br>
photons/s, respectively, in 2π solid angle. The calculated values of the photon conversion efficiency were 1.3 × 10 <br>
<sup>- 8</sup><br>
for Pt Kα1 and 9 × 10 <br>
<sup>- 9</sup><br>
for W Kα1. The additional experimental bremsstrahlung-induced dose measurements and modeling were performed. The correspondence between experimental and modeling data for the dose evaluation was found. The dose rate up to 25 μ Sv/h was measured on the top of the X-ray generation chamber. <br>
</p>}},
author = {{Reklaitis, Jonas and Barkauskas, Vytenis and Plukis, Artūras and Kovalevskij, Vitalij and Gaspariūnas, Mindaugas and Germanas, Darius and Garankin, Jevgenij and Stanislauskas, Tomas and Jasiūnas, Kęstutis and Remeikis, Vidmantas}},
issn = {{0946-2171}},
language = {{eng}},
month = {{03}},
number = {{3}},
publisher = {{Springer}},
series = {{Applied Physics B: Lasers and Optics}},
title = {{Emission and dose characterization of the 1 kHz repetition rate high-Z metal K
<sub>α</sub>
source driven by 20 mJ femtosecond pulses}},
url = {{http://dx.doi.org/10.1007/s00340-019-7155-6}},
doi = {{10.1007/s00340-019-7155-6}},
volume = {{125}},
year = {{2019}},
}