Tibial Component Undersizing Is Related to High Degrees of Implant Migration Following Cementless Total Knee Arthroplasty : A Study of Radiostereometric Analysis Data for 111 Patients with 2-Year Follow-up

Andersen, Mikkel Rathsach ; Winther, Nikolaj ; Lind, Thomas ; Schrøder, Henrik ; Flivik, Gunnar LU and Petersen, Michael Mørk (2023) In JBJS Open Access 8(3).
Abstract

Background: Radiostereometric analysis (RSA) studies have shown that the continuous migration of tibial components is predictive of aseptic loosening following total knee arthroplasty (TKA). In the present study, we investigated whether accurate sizing and placement of tibial components are related to the degree of implant migration as measured with use of RSA.Methods:A total of 111 patients who underwent TKA surgery with a cementless tibial component were followed for a period of 2 years postoperatively, during which implant migration was assessed with use of RSA. RSA was performed within 7 days postoperatively and after 3, 6, 12, and 24 months. Postoperative radiographs were evaluated for component size and placement in the tibia. The... (More)

Background: Radiostereometric analysis (RSA) studies have shown that the continuous migration of tibial components is predictive of aseptic loosening following total knee arthroplasty (TKA). In the present study, we investigated whether accurate sizing and placement of tibial components are related to the degree of implant migration as measured with use of RSA.Methods:A total of 111 patients who underwent TKA surgery with a cementless tibial component were followed for a period of 2 years postoperatively, during which implant migration was assessed with use of RSA. RSA was performed within 7 days postoperatively and after 3, 6, 12, and 24 months. Postoperative radiographs were evaluated for component size and placement in the tibia. The evaluations were performed by experienced knee surgeons who were blinded to the migration data and clinical outcomes. A multivariable linear regression analysis was conducted.Results:Continuous implant migration (i.e., migration occurring between 12 and 24 months postoperatively) had a negative association with tibial component size (coefficient [B], -0.2; 95% confidence interval [CI], -0.33 to -0.08). Subsidence was associated with the absence of posterior cortical bone support (B, -0.7; 95% CI, -1.09 to -0.28), the absence of lateral cortical bone support (B, 0.8; 95% CI, 0.29 to 1.37), frontal-plane varus malalignment (B, 0.6; 95% CI, 0.12 to 1.16), and component undersizing (B, -0.4; 95% CI, -0.06 to -0.68). Posterior tilt was associated only with undersizing (B, 0.6; 95% CI, 0.27 to 1.11).Conclusions:Undersized cementless tibial components are at a higher risk for poor fixation with continuous migration following TKA. Therefore, a higher risk of aseptic loosening should be expected.Level of Evidence:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
JBJS Open Access
volume
8
issue
3
article number
00032
publisher
Lippincott Williams & Wilkins
external identifiers
  • pmid:37575962
  • scopus:85168136709
ISSN
2472-7245
DOI
10.2106/JBJS.OA.23.00032
language
English
LU publication?
yes
id
06561ba3-14e3-418a-8253-406ead7d240c
date added to LUP
2023-10-31 14:58:37
date last changed
2024-04-19 04:14:26
@article{06561ba3-14e3-418a-8253-406ead7d240c,
  abstract     = {{<p>Background: Radiostereometric analysis (RSA) studies have shown that the continuous migration of tibial components is predictive of aseptic loosening following total knee arthroplasty (TKA). In the present study, we investigated whether accurate sizing and placement of tibial components are related to the degree of implant migration as measured with use of RSA.Methods:A total of 111 patients who underwent TKA surgery with a cementless tibial component were followed for a period of 2 years postoperatively, during which implant migration was assessed with use of RSA. RSA was performed within 7 days postoperatively and after 3, 6, 12, and 24 months. Postoperative radiographs were evaluated for component size and placement in the tibia. The evaluations were performed by experienced knee surgeons who were blinded to the migration data and clinical outcomes. A multivariable linear regression analysis was conducted.Results:Continuous implant migration (i.e., migration occurring between 12 and 24 months postoperatively) had a negative association with tibial component size (coefficient [B], -0.2; 95% confidence interval [CI], -0.33 to -0.08). Subsidence was associated with the absence of posterior cortical bone support (B, -0.7; 95% CI, -1.09 to -0.28), the absence of lateral cortical bone support (B, 0.8; 95% CI, 0.29 to 1.37), frontal-plane varus malalignment (B, 0.6; 95% CI, 0.12 to 1.16), and component undersizing (B, -0.4; 95% CI, -0.06 to -0.68). Posterior tilt was associated only with undersizing (B, 0.6; 95% CI, 0.27 to 1.11).Conclusions:Undersized cementless tibial components are at a higher risk for poor fixation with continuous migration following TKA. Therefore, a higher risk of aseptic loosening should be expected.Level of Evidence:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.</p>}},
  author       = {{Andersen, Mikkel Rathsach and Winther, Nikolaj and Lind, Thomas and Schrøder, Henrik and Flivik, Gunnar and Petersen, Michael Mørk}},
  issn         = {{2472-7245}},
  language     = {{eng}},
  number       = {{3}},
  publisher    = {{Lippincott Williams & Wilkins}},
  series       = {{JBJS Open Access}},
  title        = {{Tibial Component Undersizing Is Related to High Degrees of Implant Migration Following Cementless Total Knee Arthroplasty : A Study of Radiostereometric Analysis Data for 111 Patients with 2-Year Follow-up}},
  url          = {{http://dx.doi.org/10.2106/JBJS.OA.23.00032}},
  doi          = {{10.2106/JBJS.OA.23.00032}},
  volume       = {{8}},
  year         = {{2023}},
}