The influence of RBE variations in a clinical proton treatment plan for a hypopharynx cancer

Tilly, N ; Johansson, J ; Isacsson, U ; Medin, Joakim LU ; Blomquist, E ; Grusell, E and Glimelius, B (2005) In Physics in Medicine and Biology 50(12). p.2765-2777
Abstract
Currently, most clinical range-modulated proton beams are assumed to have a fixed overall relative biological effectiveness (RBE) of 1.1. However, it is well known that the RBE increases with depth in the spread-out Bragg peak (SOBP) and becomes about 10% higher than mid-SOBP RBE at 2 mm from the distal edge (Paganetti 2003 Technol. Cancer Res. Treat. 2 413-26) and can reach values of 1.3-1.4 in vitro at the distal edge (Robertson et al 1975 Cancer 35 1664-77, Courdi et al 1994 Br. J. Radiol. 67 800-4). We present a fast method for applying a variable RBE correction with linear energy transfer (LET) dependent tissue-specific parameters based on the alpha(ref)/beta(ref) ratios suitable for implementation in a treatment planning system. The... (More)
Currently, most clinical range-modulated proton beams are assumed to have a fixed overall relative biological effectiveness (RBE) of 1.1. However, it is well known that the RBE increases with depth in the spread-out Bragg peak (SOBP) and becomes about 10% higher than mid-SOBP RBE at 2 mm from the distal edge (Paganetti 2003 Technol. Cancer Res. Treat. 2 413-26) and can reach values of 1.3-1.4 in vitro at the distal edge (Robertson et al 1975 Cancer 35 1664-77, Courdi et al 1994 Br. J. Radiol. 67 800-4). We present a fast method for applying a variable RBE correction with linear energy transfer (LET) dependent tissue-specific parameters based on the alpha(ref)/beta(ref) ratios suitable for implementation in a treatment planning system. The influence of applying this variable RBE correction on a clinical multiple beam proton dose plan is presented here. The treatment plan is evaluated by RBE weighted dose volume histograms (DVHs) and the calculation of tumour control probability (TCP) and normal tissue complication probability (NTCP) values. The variable RBE correction yields DVHs for the clinical target volumes (CTVs), a primary advanced hypopharynx cancer and subclinical disease in the lymph nodes, that are slightly higher than those achieved by multiplying the absorbed dose with RBE = 1.1. Although, more importantly, the RBE weighted DVH for an organ at risk, the spinal cord is considerably increased for the variable RBE. As the spinal cord in this particular case is located 8 mm behind the planning target volume (PTV) and hence receives only low total doses, the NTCP values are zero in spite of the significant increase in the RBE weighted DVHs for the variable RBE. However, high NTCP values for the non-target normal tissue were obtained when applying the variable RBE correction. As RBE variations tend to be smaller for in vivo systems, this study-based on in vitro data since human tissue RBE values are scarce and have large uncertainties-can be interpreted as showing the upper limits of the possible effects of utilizing a variable RBE correction. In conclusion, the results obtained here still indicate a significant difference in introducing a variable RBE compared to applying a generic RBE of 1.1, suggesting it is worth considering such a correction in clinical proton therapy planning, especially when risk organs are located immediately behind the target volume. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Physics in Medicine and Biology
volume
50
issue
12
pages
2765 - 2777
publisher
IOP Publishing
external identifiers
  • pmid:15930601
  • wos:000230710200003
  • scopus:20044388910
ISSN
1361-6560
DOI
10.1088/0031-9155/50/12/003
language
English
LU publication?
yes
id
0c479afe-4705-43d8-96ff-f5acbc7dc715 (old id 894993)
date added to LUP
2016-04-01 11:45:19
date last changed
2022-02-10 21:03:34
@article{0c479afe-4705-43d8-96ff-f5acbc7dc715,
  abstract     = {{Currently, most clinical range-modulated proton beams are assumed to have a fixed overall relative biological effectiveness (RBE) of 1.1. However, it is well known that the RBE increases with depth in the spread-out Bragg peak (SOBP) and becomes about 10% higher than mid-SOBP RBE at 2 mm from the distal edge (Paganetti 2003 Technol. Cancer Res. Treat. 2 413-26) and can reach values of 1.3-1.4 in vitro at the distal edge (Robertson et al 1975 Cancer 35 1664-77, Courdi et al 1994 Br. J. Radiol. 67 800-4). We present a fast method for applying a variable RBE correction with linear energy transfer (LET) dependent tissue-specific parameters based on the alpha(ref)/beta(ref) ratios suitable for implementation in a treatment planning system. The influence of applying this variable RBE correction on a clinical multiple beam proton dose plan is presented here. The treatment plan is evaluated by RBE weighted dose volume histograms (DVHs) and the calculation of tumour control probability (TCP) and normal tissue complication probability (NTCP) values. The variable RBE correction yields DVHs for the clinical target volumes (CTVs), a primary advanced hypopharynx cancer and subclinical disease in the lymph nodes, that are slightly higher than those achieved by multiplying the absorbed dose with RBE = 1.1. Although, more importantly, the RBE weighted DVH for an organ at risk, the spinal cord is considerably increased for the variable RBE. As the spinal cord in this particular case is located 8 mm behind the planning target volume (PTV) and hence receives only low total doses, the NTCP values are zero in spite of the significant increase in the RBE weighted DVHs for the variable RBE. However, high NTCP values for the non-target normal tissue were obtained when applying the variable RBE correction. As RBE variations tend to be smaller for in vivo systems, this study-based on in vitro data since human tissue RBE values are scarce and have large uncertainties-can be interpreted as showing the upper limits of the possible effects of utilizing a variable RBE correction. In conclusion, the results obtained here still indicate a significant difference in introducing a variable RBE compared to applying a generic RBE of 1.1, suggesting it is worth considering such a correction in clinical proton therapy planning, especially when risk organs are located immediately behind the target volume.}},
  author       = {{Tilly, N and Johansson, J and Isacsson, U and Medin, Joakim and Blomquist, E and Grusell, E and Glimelius, B}},
  issn         = {{1361-6560}},
  language     = {{eng}},
  number       = {{12}},
  pages        = {{2765--2777}},
  publisher    = {{IOP Publishing}},
  series       = {{Physics in Medicine and Biology}},
  title        = {{The influence of RBE variations in a clinical proton treatment plan for a hypopharynx cancer}},
  url          = {{http://dx.doi.org/10.1088/0031-9155/50/12/003}},
  doi          = {{10.1088/0031-9155/50/12/003}},
  volume       = {{50}},
  year         = {{2005}},
}