Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Environmental correlates of impaired lung function in non-smokers with severe alpha 1-antitrypsin deficiency (PiZZ)

Piitulainen, Eeva LU ; Tornling, Göran and Eriksson, Sten LU (1998) In Thorax 53(11). p.939-943
Abstract
BACKGROUND: Active smoking is the most important risk factor for pulmonary emphysema in subjects with severe alpha 1-antitrypsin (AAT) deficiency. The aim of this study was to analyse the effects of environmental risk factors other than active smoking on lung function and on respiratory symptoms in non-smoking PiZZ individuals. METHODS: Lifetime exposure to passive smoking, domiciliary use of a kerosene (paraffin) heater or gas cooker, and all occupations since leaving school were reported by 205 non-smoking PiZZ individuals (95 men and 110 women) included in the Swedish AAT deficiency register. Lung function test results and histories of respiratory symptoms (chronic bronchitis, recurrent wheezing, and exertional dyspnoea) were elicited... (More)
BACKGROUND: Active smoking is the most important risk factor for pulmonary emphysema in subjects with severe alpha 1-antitrypsin (AAT) deficiency. The aim of this study was to analyse the effects of environmental risk factors other than active smoking on lung function and on respiratory symptoms in non-smoking PiZZ individuals. METHODS: Lifetime exposure to passive smoking, domiciliary use of a kerosene (paraffin) heater or gas cooker, and all occupations since leaving school were reported by 205 non-smoking PiZZ individuals (95 men and 110 women) included in the Swedish AAT deficiency register. Lung function test results and histories of respiratory symptoms (chronic bronchitis, recurrent wheezing, and exertional dyspnoea) were elicited from the AAT register records. RESULTS: After adjustment for age, agricultural employment and domiciliary kerosene heater usage, but not gas cooker usage or passive smoking, were both associated with significantly decreased lung function. Multiple linear regression analysis showed age, sex, kerosene heater usage, and agricultural employment to be independent determinants of lung function impairment. Age and passive smoking for 10 years or more, both at home and at the work place, were associated with the presence of chronic bronchitis. Age and agricultural employment for > or = 10 years were associated with recurrent wheezing and exertional dyspnoea. CONCLUSIONS: Domiciliary kerosene heater usage and an agricultural occupation therefore appear to be environmental factors associated with decreased lung function in non-smoking PiZZ individuals, and passive smoking is associated with an increased frequency of chronic bronchitis, but not with impaired lung function. (Less)
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
alpha 1-antitrypsin deficiency, passive smoking, indoor air pollution, occupational exposure, emphysema
in
Thorax
volume
53
issue
11
pages
939 - 943
publisher
BMJ Publishing Group
external identifiers
  • pmid:10193391
ISSN
1468-3296
language
English
LU publication?
yes
id
0fb02c16-16ef-4abb-a23d-44e84d686800 (old id 1113613)
alternative location
http://thorax.bmj.com/cgi/content/full/53/11/939
date added to LUP
2016-04-01 16:08:39
date last changed
2018-11-21 20:39:05
@article{0fb02c16-16ef-4abb-a23d-44e84d686800,
  abstract     = {{BACKGROUND: Active smoking is the most important risk factor for pulmonary emphysema in subjects with severe alpha 1-antitrypsin (AAT) deficiency. The aim of this study was to analyse the effects of environmental risk factors other than active smoking on lung function and on respiratory symptoms in non-smoking PiZZ individuals. METHODS: Lifetime exposure to passive smoking, domiciliary use of a kerosene (paraffin) heater or gas cooker, and all occupations since leaving school were reported by 205 non-smoking PiZZ individuals (95 men and 110 women) included in the Swedish AAT deficiency register. Lung function test results and histories of respiratory symptoms (chronic bronchitis, recurrent wheezing, and exertional dyspnoea) were elicited from the AAT register records. RESULTS: After adjustment for age, agricultural employment and domiciliary kerosene heater usage, but not gas cooker usage or passive smoking, were both associated with significantly decreased lung function. Multiple linear regression analysis showed age, sex, kerosene heater usage, and agricultural employment to be independent determinants of lung function impairment. Age and passive smoking for 10 years or more, both at home and at the work place, were associated with the presence of chronic bronchitis. Age and agricultural employment for > or = 10 years were associated with recurrent wheezing and exertional dyspnoea. CONCLUSIONS: Domiciliary kerosene heater usage and an agricultural occupation therefore appear to be environmental factors associated with decreased lung function in non-smoking PiZZ individuals, and passive smoking is associated with an increased frequency of chronic bronchitis, but not with impaired lung function.}},
  author       = {{Piitulainen, Eeva and Tornling, Göran and Eriksson, Sten}},
  issn         = {{1468-3296}},
  keywords     = {{alpha 1-antitrypsin deficiency; passive smoking; indoor air pollution; occupational exposure; emphysema}},
  language     = {{eng}},
  number       = {{11}},
  pages        = {{939--943}},
  publisher    = {{BMJ Publishing Group}},
  series       = {{Thorax}},
  title        = {{Environmental correlates of impaired lung function in non-smokers with severe alpha 1-antitrypsin deficiency (PiZZ)}},
  url          = {{http://thorax.bmj.com/cgi/content/full/53/11/939}},
  volume       = {{53}},
  year         = {{1998}},
}