High performance slit-less spectrometer for soft x-ray emission spectroscopy
(2006) In Review of Scientific Instruments 77(6).- Abstract
We have designed and constructed a new flat-field-type slit-less soft x-ray emission spectrometer that enables high detection efficiency and high energy resolution in the energy range of 250-1000 eV. The energy resolution is optimized in the C 1s and O 1s regions, where the maximum energy resolution of 2500 (E/ΔE) is expected using a focused beam whose spot size is 5 μm full width at half maximum in the vertical direction. A distortion of the linear profile of the focused image on the charge-coupled device (CCD) detector is successfully removed by using a cylindrical grating. This enabled us to apply a super-resolution reconstruction technique to compensate for the lack of spatial resolution of the CCD detector.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/0fd1f32e-853e-4765-9856-9e178f5baa63
- author
- Tokushima, T.
LU
; Harada, Yoshihisa
; Ohashi, H.
; Senba, Y.
and Shin, S.
- publishing date
- 2006
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Review of Scientific Instruments
- volume
- 77
- issue
- 6
- article number
- 063107
- publisher
- American Institute of Physics (AIP)
- external identifiers
-
- scopus:33745713677
- ISSN
- 0034-6748
- DOI
- 10.1063/1.2204623
- language
- English
- LU publication?
- no
- id
- 0fd1f32e-853e-4765-9856-9e178f5baa63
- date added to LUP
- 2023-08-25 16:59:16
- date last changed
- 2025-10-14 12:41:40
@article{0fd1f32e-853e-4765-9856-9e178f5baa63,
abstract = {{<p>We have designed and constructed a new flat-field-type slit-less soft x-ray emission spectrometer that enables high detection efficiency and high energy resolution in the energy range of 250-1000 eV. The energy resolution is optimized in the C 1s and O 1s regions, where the maximum energy resolution of 2500 (E/ΔE) is expected using a focused beam whose spot size is 5 μm full width at half maximum in the vertical direction. A distortion of the linear profile of the focused image on the charge-coupled device (CCD) detector is successfully removed by using a cylindrical grating. This enabled us to apply a super-resolution reconstruction technique to compensate for the lack of spatial resolution of the CCD detector.</p>}},
author = {{Tokushima, T. and Harada, Yoshihisa and Ohashi, H. and Senba, Y. and Shin, S.}},
issn = {{0034-6748}},
language = {{eng}},
number = {{6}},
publisher = {{American Institute of Physics (AIP)}},
series = {{Review of Scientific Instruments}},
title = {{High performance slit-less spectrometer for soft x-ray emission spectroscopy}},
url = {{http://dx.doi.org/10.1063/1.2204623}},
doi = {{10.1063/1.2204623}},
volume = {{77}},
year = {{2006}},
}