Advanced

Automated high-performance liquid chromatographic determination of 5-S-cysteinyl-3,4-dihydroxyphenylalanine in urine

Kagedal, Bertil; Källberg, Magnus; Årstrand, Kerstin and Hansson, Christer LU (1989) In Journal of Chromatography A 473. p.359-370
Abstract
An automated high-performance liquid chromatographic (HPLC) method has been developed for measurement of 5-S-cysteinyl-DOPA in urine (DOPA = 3,4-dihydroxyphenylalanine). The urinary sample was injected into an HPLC boronate column. With a mobile phase of 0.1 M phosphate buffer containing 0.2 mM disodium ethylenediaminetetraacetate (Na2EDTA) (pH 6.0) mixed with methanol (9:1), 5-S-cysteinyl-DOPA was adsorbed while most other compounds were washed away. By column switching, the column flow was reversed and 5-S-cysteinyl-DOPA was desorbed by a mobile phase of 0.1 M formic acid and 0.2 mM Na2EDTA at pH 3.0 and chromatographed on a reversed-phase column. The precision, as estimated from repeated analysis of an urinary sample and from duplicate... (More)
An automated high-performance liquid chromatographic (HPLC) method has been developed for measurement of 5-S-cysteinyl-DOPA in urine (DOPA = 3,4-dihydroxyphenylalanine). The urinary sample was injected into an HPLC boronate column. With a mobile phase of 0.1 M phosphate buffer containing 0.2 mM disodium ethylenediaminetetraacetate (Na2EDTA) (pH 6.0) mixed with methanol (9:1), 5-S-cysteinyl-DOPA was adsorbed while most other compounds were washed away. By column switching, the column flow was reversed and 5-S-cysteinyl-DOPA was desorbed by a mobile phase of 0.1 M formic acid and 0.2 mM Na2EDTA at pH 3.0 and chromatographed on a reversed-phase column. The precision, as estimated from repeated analysis of an urinary sample and from duplicate analysis of a number of samples, ranged from 1.4 to 5.2% (coefficient of variation), and the analytical recovery was 93 +/- 4.1%. The method is suitable for use in the clinical laboratory. (Less)
Please use this url to cite or link to this publication:
author
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Chromatography A
volume
473
pages
359 - 370
publisher
Elsevier
external identifiers
  • pmid:2504759
  • scopus:0024364327
ISSN
0021-9673
DOI
10.1016/S0021-9673(00)91320-7
language
English
LU publication?
yes
id
1f9dc49a-d43e-41fb-ae7b-bcfd150ae31f (old id 1104709)
date added to LUP
2008-08-06 13:53:35
date last changed
2017-08-06 04:35:38
@article{1f9dc49a-d43e-41fb-ae7b-bcfd150ae31f,
  abstract     = {An automated high-performance liquid chromatographic (HPLC) method has been developed for measurement of 5-S-cysteinyl-DOPA in urine (DOPA = 3,4-dihydroxyphenylalanine). The urinary sample was injected into an HPLC boronate column. With a mobile phase of 0.1 M phosphate buffer containing 0.2 mM disodium ethylenediaminetetraacetate (Na2EDTA) (pH 6.0) mixed with methanol (9:1), 5-S-cysteinyl-DOPA was adsorbed while most other compounds were washed away. By column switching, the column flow was reversed and 5-S-cysteinyl-DOPA was desorbed by a mobile phase of 0.1 M formic acid and 0.2 mM Na2EDTA at pH 3.0 and chromatographed on a reversed-phase column. The precision, as estimated from repeated analysis of an urinary sample and from duplicate analysis of a number of samples, ranged from 1.4 to 5.2% (coefficient of variation), and the analytical recovery was 93 +/- 4.1%. The method is suitable for use in the clinical laboratory.},
  author       = {Kagedal, Bertil and Källberg, Magnus and Årstrand, Kerstin and Hansson, Christer},
  issn         = {0021-9673},
  language     = {eng},
  pages        = {359--370},
  publisher    = {Elsevier},
  series       = {Journal of Chromatography A},
  title        = {Automated high-performance liquid chromatographic determination of 5-S-cysteinyl-3,4-dihydroxyphenylalanine in urine},