Serum cystatin C, determined by a rapid, automated particle-enhanced turbidimetric method, is a better marker than serum creatinine for glomerular filtration rate
(1994) In Clinical Chemistry 40(10). p.1921-1926- Abstract
- We describe a fully automated particle-enhanced turbidimetric assay for cystatin C in undiluted serum and EDTA-plasma. The throughput is 90 samples per hour and urgent samples can be analyzed in 7 min. The assay range (0.4-14.1 mg/L) covers the concentration range in health and disease. The within- and between-run imprecision is 0.9% and 2.2%, respectively. Analytical recovery of additions of recombinant cystatin C averaged 98%. Rheumatoid factors (< or = 323,000 IU/L), bilirubin (< or = 150 mumol/L), hemoglobin (< or = 1.2 g/L), and triglycerides (< or = 8.5 mmol/L) do not interfere in the assay. In view of the superior (by ROC analysis) diagnostic accuracy of serum concentrations of cystatin C for reduced glomerular... (More)
- We describe a fully automated particle-enhanced turbidimetric assay for cystatin C in undiluted serum and EDTA-plasma. The throughput is 90 samples per hour and urgent samples can be analyzed in 7 min. The assay range (0.4-14.1 mg/L) covers the concentration range in health and disease. The within- and between-run imprecision is 0.9% and 2.2%, respectively. Analytical recovery of additions of recombinant cystatin C averaged 98%. Rheumatoid factors (< or = 323,000 IU/L), bilirubin (< or = 150 mumol/L), hemoglobin (< or = 1.2 g/L), and triglycerides (< or = 8.5 mmol/L) do not interfere in the assay. In view of the superior (by ROC analysis) diagnostic accuracy of serum concentrations of cystatin C for reduced glomerular filtration rate (GFR) in comparison with creatinine, cystatin C seems an attractive alternative to creatinine for estimation of GFR. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1108363
- author
- Kyhse-Andersen, Jan
; Schmidt, Camilla
; Nordin, Gunnar
; Andersson, Britta
; Nilsson-Ehle, Peter
LU
; Lindström, Veronica
LU
and Grubb, Anders LU
- organization
- publishing date
- 1994
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Clinical Chemistry
- volume
- 40
- issue
- 10
- pages
- 1921 - 1926
- publisher
- American Association for Clinical Chemistry
- external identifiers
-
- pmid:7923773
- scopus:0028138577
- ISSN
- 0009-9147
- language
- English
- LU publication?
- yes
- id
- ddfbcacb-54d6-4460-8646-4b4279a90631 (old id 1108363)
- alternative location
- http://www.clinchem.org/cgi/reprint/40/10/1921
- date added to LUP
- 2016-04-01 12:02:22
- date last changed
- 2021-09-05 04:42:21
@article{ddfbcacb-54d6-4460-8646-4b4279a90631, abstract = {{We describe a fully automated particle-enhanced turbidimetric assay for cystatin C in undiluted serum and EDTA-plasma. The throughput is 90 samples per hour and urgent samples can be analyzed in 7 min. The assay range (0.4-14.1 mg/L) covers the concentration range in health and disease. The within- and between-run imprecision is 0.9% and 2.2%, respectively. Analytical recovery of additions of recombinant cystatin C averaged 98%. Rheumatoid factors (< or = 323,000 IU/L), bilirubin (< or = 150 mumol/L), hemoglobin (< or = 1.2 g/L), and triglycerides (< or = 8.5 mmol/L) do not interfere in the assay. In view of the superior (by ROC analysis) diagnostic accuracy of serum concentrations of cystatin C for reduced glomerular filtration rate (GFR) in comparison with creatinine, cystatin C seems an attractive alternative to creatinine for estimation of GFR.}}, author = {{Kyhse-Andersen, Jan and Schmidt, Camilla and Nordin, Gunnar and Andersson, Britta and Nilsson-Ehle, Peter and Lindström, Veronica and Grubb, Anders}}, issn = {{0009-9147}}, language = {{eng}}, number = {{10}}, pages = {{1921--1926}}, publisher = {{American Association for Clinical Chemistry}}, series = {{Clinical Chemistry}}, title = {{Serum cystatin C, determined by a rapid, automated particle-enhanced turbidimetric method, is a better marker than serum creatinine for glomerular filtration rate}}, url = {{http://www.clinchem.org/cgi/reprint/40/10/1921}}, volume = {{40}}, year = {{1994}}, }