Feasibility of patient specific aortic blood flow CFD simulation
(2006) 4190. p.257-263- Abstract
- Patient specific modelling of the blood flow through the human aorta is performed using computational fluid dynamics (CFD) and magnetic resonance imaging (MRI). Velocity patterns are compared between computer simulations and measurements. The workflow includes several steps: MRI measurement to obtain both geometry and velocity, an automatic levelset segmentation followed by meshing of the geometrical model and CFD setup to perform the simulations follwed by the actual simulations. The computational results agree well with the measured data.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1135887
- author
- Svensson, Johan ; Gardhagen, Roland ; Heiberg, Einar LU ; Ebbers, Tino ; Loyd, Dan ; Lanne, Toste and Karlsson, Matts
- organization
- publishing date
- 2006
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- host publication
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
- volume
- 4190
- pages
- 257 - 263
- publisher
- Springer
- external identifiers
-
- pmid:17354898
- DOI
- 10.1007/11866565
- language
- English
- LU publication?
- yes
- id
- 98984406-0bcf-42f7-afbc-1ba65206b903 (old id 1135887)
- date added to LUP
- 2016-04-04 09:57:47
- date last changed
- 2021-11-19 09:15:41
@inproceedings{98984406-0bcf-42f7-afbc-1ba65206b903, abstract = {{Patient specific modelling of the blood flow through the human aorta is performed using computational fluid dynamics (CFD) and magnetic resonance imaging (MRI). Velocity patterns are compared between computer simulations and measurements. The workflow includes several steps: MRI measurement to obtain both geometry and velocity, an automatic levelset segmentation followed by meshing of the geometrical model and CFD setup to perform the simulations follwed by the actual simulations. The computational results agree well with the measured data.}}, author = {{Svensson, Johan and Gardhagen, Roland and Heiberg, Einar and Ebbers, Tino and Loyd, Dan and Lanne, Toste and Karlsson, Matts}}, booktitle = {{Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention}}, language = {{eng}}, pages = {{257--263}}, publisher = {{Springer}}, title = {{Feasibility of patient specific aortic blood flow CFD simulation}}, url = {{http://dx.doi.org/10.1007/11866565}}, doi = {{10.1007/11866565}}, volume = {{4190}}, year = {{2006}}, }