Flame Sizes in a Small Scale Stack: Pilot Experiments
(1995) In LUTVDG/TVBB--3077--SE- Abstract
- For the last many decades industry and insurance companies have been interested in protecting high racked goods from rapid fire growth. This has mainly been done by installing sprinklers of various types and designs in order to either extinguish the fire or control it. The efficiency of such protection measures is, however, very much dependant on the geometry of the stacks, their height, floor area, the flue spacing, etc. and the flammable characteristics of the stored goods. A research project was initiated by the Swedish Fire Research Board (BRANDFORSK) to throw some light on the aforementioned geometric aspects of the problem. The main part of the project is to be carried out at the Swedish National Testing and Research Institute (SP)... (More)
- For the last many decades industry and insurance companies have been interested in protecting high racked goods from rapid fire growth. This has mainly been done by installing sprinklers of various types and designs in order to either extinguish the fire or control it. The efficiency of such protection measures is, however, very much dependant on the geometry of the stacks, their height, floor area, the flue spacing, etc. and the flammable characteristics of the stored goods. A research project was initiated by the Swedish Fire Research Board (BRANDFORSK) to throw some light on the aforementioned geometric aspects of the problem. The main part of the project is to be carried out at the Swedish National Testing and Research Institute (SP) but a pilot study was initiated at Lund University, with some participation from scientists at SP. The work carried out at Lund University consisted of two parts. Firstly, Thomas [l] carried out a litterature survey of earlier experiments and summarized the main findings. Secondly, some experiments were made on reduced scale to examine the effect of the geometry of a pile of inert goods on the flames from a burner. This report describes the work carried out in this second part of the pilot study. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1267618
- author
- Karlsson, Björn ; Thomas, Philip H and Holmstedt, Göran LU
- organization
- publishing date
- 1995
- type
- Book/Report
- publication status
- published
- subject
- in
- LUTVDG/TVBB--3077--SE
- pages
- 10 pages
- publisher
- Department of Fire Safety Engineering and Systems Safety, Lund University
- report number
- 3077
- ISSN
- 1102-8246
- language
- English
- LU publication?
- yes
- id
- 6d4662b5-2ec2-4eab-95eb-72a773e6bc9e (old id 1267618)
- date added to LUP
- 2016-04-01 17:14:18
- date last changed
- 2018-11-21 20:47:42
@techreport{6d4662b5-2ec2-4eab-95eb-72a773e6bc9e, abstract = {{For the last many decades industry and insurance companies have been interested in protecting high racked goods from rapid fire growth. This has mainly been done by installing sprinklers of various types and designs in order to either extinguish the fire or control it. The efficiency of such protection measures is, however, very much dependant on the geometry of the stacks, their height, floor area, the flue spacing, etc. and the flammable characteristics of the stored goods. A research project was initiated by the Swedish Fire Research Board (BRANDFORSK) to throw some light on the aforementioned geometric aspects of the problem. The main part of the project is to be carried out at the Swedish National Testing and Research Institute (SP) but a pilot study was initiated at Lund University, with some participation from scientists at SP. The work carried out at Lund University consisted of two parts. Firstly, Thomas [l] carried out a litterature survey of earlier experiments and summarized the main findings. Secondly, some experiments were made on reduced scale to examine the effect of the geometry of a pile of inert goods on the flames from a burner. This report describes the work carried out in this second part of the pilot study.}}, author = {{Karlsson, Björn and Thomas, Philip H and Holmstedt, Göran}}, institution = {{Department of Fire Safety Engineering and Systems Safety, Lund University}}, issn = {{1102-8246}}, language = {{eng}}, number = {{3077}}, series = {{LUTVDG/TVBB--3077--SE}}, title = {{Flame Sizes in a Small Scale Stack: Pilot Experiments}}, url = {{https://lup.lub.lu.se/search/files/4916739/4450574.pdf}}, year = {{1995}}, }