Critical degrees of saturation at freezing of porous and brittle materials

Fagerlund, Göran LU (1973) In Summary + Report 34,40,41
Abstract
This thesis is based on experimental work carried out during the period

1968-1972. The whole investigation is sponsored by the Swedish Council

for Building Research and has been performed at the department of Building

Materials at the Lund Institute of Technology.



The thesis treats the problem frost resistance of building materials,

a problem which is far from beeing solved despite much scientific work

in many countries. According to the author the main reason for this

lack of success is, that the problem of frost resistance is not only

a function of materials properties but also of properties of the environment

in which the materials are used.... (More)
This thesis is based on experimental work carried out during the period

1968-1972. The whole investigation is sponsored by the Swedish Council

for Building Research and has been performed at the department of Building

Materials at the Lund Institute of Technology.



The thesis treats the problem frost resistance of building materials,

a problem which is far from beeing solved despite much scientific work

in many countries. According to the author the main reason for this

lack of success is, that the problem of frost resistance is not only

a function of materials properties but also of properties of the environment

in which the materials are used. Hence, in order to solve the problem it is necessary to investigate separately the effect of material properties and the effect of environmental properties on the frost resistance of a material... (Less)
Please use this url to cite or link to this publication:
author
opponent
  • Warris, Birger, Euroc
organization
alternative title
Kritiska vattenmättnadsgrader i samband med frysning av porösa och spröda material
publishing date
type
Thesis
publication status
published
subject
keywords
resistance, freezing mechanism, freezing test method, pore size distribution(determination), saturation (degree of), water absorption, frost
in
Summary + Report 34,40,41
pages
500 pages
publisher
Tid. Institutionen för byggnadsteknik, Tekniska högskolan i Lund
defense location
Sektionen Väg och Vatten, hörsal V:A, John Ericssons väg 1
defense date
1973-05-22 10:00
ISSN
0346-864X
language
English
LU publication?
yes
id
011af224-c29c-4b20-9de5-880ae711a31d (old id 1273027)
date added to LUP
2010-03-03 10:23:24
date last changed
2016-09-19 08:44:58
@phdthesis{011af224-c29c-4b20-9de5-880ae711a31d,
  abstract     = {This thesis is based on experimental work carried out during the period<br/><br>
1968-1972. The whole investigation is sponsored by the Swedish Council<br/><br>
for Building Research and has been performed at the department of Building<br/><br>
Materials at the Lund Institute of Technology.<br/><br>
<br/><br>
The thesis treats the problem frost resistance of building materials,<br/><br>
a problem which is far from beeing solved despite much scientific work<br/><br>
in many countries. According to the author the main reason for this<br/><br>
lack of success is, that the problem of frost resistance is not only<br/><br>
a function of materials properties but also of properties of the environment<br/><br>
in which the materials are used. Hence, in order to solve the problem it is necessary to investigate separately the effect of material properties and the effect of environmental properties on the frost resistance of a material...},
  author       = {Fagerlund, Göran},
  issn         = {0346-864X},
  keyword      = {resistance,freezing mechanism,freezing test method,pore size distribution(determination),saturation (degree of),water absorption,frost},
  language     = {eng},
  pages        = {500},
  publisher    = {Tid. Institutionen för byggnadsteknik, Tekniska högskolan i Lund},
  school       = {Lund University},
  series       = {Summary + Report 34,40,41},
  title        = {Critical degrees of saturation at freezing of porous and brittle materials},
  year         = {1973},
}