Closed source experimental system for soft x-ray spectroscopy of radioactive materials
(2008) In Review of Scientific Instruments 79(9).- Abstract
- An instrumental and experimental setup for soft x-ray spectroscopy meeting the requirements of a closed source for radioactivity is described. The system consists of a vacuum sealed cell containing the sample, mounted on a tubing system to ensure compatibility with most standard manipulators. The soft x rays penetrate a thin x-ray window separating the interior of the cell from the vacuum in the experimental chamber. Our first results for single crystal PuO2 confirm the feasibility of experiments using the setup. The results are consistent with results of first principles calculations and previously recorded spectra obtained using a standard open source setup. The results show that the closed source experimental system can be used to... (More)
- An instrumental and experimental setup for soft x-ray spectroscopy meeting the requirements of a closed source for radioactivity is described. The system consists of a vacuum sealed cell containing the sample, mounted on a tubing system to ensure compatibility with most standard manipulators. The soft x rays penetrate a thin x-ray window separating the interior of the cell from the vacuum in the experimental chamber. Our first results for single crystal PuO2 confirm the feasibility of experiments using the setup. The results are consistent with results of first principles calculations and previously recorded spectra obtained using a standard open source setup. The results show that the closed source experimental system can be used to collect valuable experimental data from radioactive materials. c 2008 American Institute of Physics. [DOI: 10.1063/1.2991109] (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1283777
- author
- organization
- publishing date
- 2008
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Review of Scientific Instruments
- volume
- 79
- issue
- 9
- publisher
- American Institute of Physics (AIP)
- external identifiers
-
- wos:000260291800004
- scopus:54749149184
- pmid:19044400
- ISSN
- 1089-7623
- DOI
- 10.1063/1.2991109
- language
- English
- LU publication?
- yes
- id
- db544417-ca95-4ba2-9b18-8d52e79af73d (old id 1283777)
- date added to LUP
- 2016-04-01 14:01:10
- date last changed
- 2022-03-21 21:48:54
@article{db544417-ca95-4ba2-9b18-8d52e79af73d, abstract = {{An instrumental and experimental setup for soft x-ray spectroscopy meeting the requirements of a closed source for radioactivity is described. The system consists of a vacuum sealed cell containing the sample, mounted on a tubing system to ensure compatibility with most standard manipulators. The soft x rays penetrate a thin x-ray window separating the interior of the cell from the vacuum in the experimental chamber. Our first results for single crystal PuO2 confirm the feasibility of experiments using the setup. The results are consistent with results of first principles calculations and previously recorded spectra obtained using a standard open source setup. The results show that the closed source experimental system can be used to collect valuable experimental data from radioactive materials. c 2008 American Institute of Physics. [DOI: 10.1063/1.2991109]}}, author = {{Modin, A. and Butorin, S. M. and Vegelius, J. and Olsson, A. and Englund, C. -J. and Andersson, J. and Werme, L. and Nordgren, J. and Käämbre, Tanel and Skarnemark, G. and Burakov, B. E.}}, issn = {{1089-7623}}, language = {{eng}}, number = {{9}}, publisher = {{American Institute of Physics (AIP)}}, series = {{Review of Scientific Instruments}}, title = {{Closed source experimental system for soft x-ray spectroscopy of radioactive materials}}, url = {{http://dx.doi.org/10.1063/1.2991109}}, doi = {{10.1063/1.2991109}}, volume = {{79}}, year = {{2008}}, }