Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Percent ventricular pacing with managed ventricular pacing mode in standard pacemaker population

Milasinovic, Goran ; Tscheliessnigg, Karlheinz ; Boehmer, Anthonie ; Vancura, Vladimir ; Schuchert, Andreas ; Brandt, Johan LU ; Wiggenhorn, Christopher ; Hofman, Maaike and Sperze, Johannes (2008) In Europace 10(2). p.151-155
Abstract
Aims Unnecessary right ventricular pacing has deleterious effects and becomes more significant when cumulative percent ventricular pacing (Cum%VP) exceeds 40% of time. The Managed Ventricular Pacing (MVP) mode has been shown to significantly reduce the percent ventricular pacing compared to the DDD/R mode. This study assessed the percent of ventricular pacing in a standard pacemaker population programmed to MVP and for which patients it is possible to achieve a Cum%VP <= 40%. Methods and results Unselected, consecutive patients were implanted with a dual chamber pacemaker with a mean follow-up period of 76 days. The Cum%VP was calculated from device diagnostics between pre-hospital discharge (PHD) and the 1-month post implant visit. The... (More)
Aims Unnecessary right ventricular pacing has deleterious effects and becomes more significant when cumulative percent ventricular pacing (Cum%VP) exceeds 40% of time. The Managed Ventricular Pacing (MVP) mode has been shown to significantly reduce the percent ventricular pacing compared to the DDD/R mode. This study assessed the percent of ventricular pacing in a standard pacemaker population programmed to MVP and for which patients it is possible to achieve a Cum%VP <= 40%. Methods and results Unselected, consecutive patients were implanted with a dual chamber pacemaker with a mean follow-up period of 76 days. The Cum%VP was calculated from device diagnostics between pre-hospital discharge (PHD) and the 1-month post implant visit. The median Cum%VP of 107 patients (age 67.2 +/- 14 years; 53% mate) who were programmed to MVP was 3.9%. The median Cum%VP was 1.4% in patients with sinus node disease (SND) and 28.8% in patients with AV block (AVB). Cum%VP <= 40% was observed in 72% of all. patients, in 50% of AVB patients, and in 86% of SND patients. Conclusion The MVP mode is capable of achieving a tow percent of ventricular pacing in a standard pacemaker population with SND and AVB. In addition, 72% of patients in MVP mode demonstrated Cum%VP <= 40%. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
atrioventricular block, ventricular pacing, managed ventricular pacing, sinus node disease, pacing algorithms
in
Europace
volume
10
issue
2
pages
151 - 155
publisher
Oxford University Press
external identifiers
  • wos:000254031700005
  • scopus:41949099386
ISSN
1532-2092
DOI
10.1093/europace/eum288
language
English
LU publication?
yes
id
12a05cb7-3dcc-40d0-a923-f2f39aa6c4c4 (old id 1186245)
date added to LUP
2016-04-01 12:08:01
date last changed
2022-01-26 23:14:10
@article{12a05cb7-3dcc-40d0-a923-f2f39aa6c4c4,
  abstract     = {{Aims Unnecessary right ventricular pacing has deleterious effects and becomes more significant when cumulative percent ventricular pacing (Cum%VP) exceeds 40% of time. The Managed Ventricular Pacing (MVP) mode has been shown to significantly reduce the percent ventricular pacing compared to the DDD/R mode. This study assessed the percent of ventricular pacing in a standard pacemaker population programmed to MVP and for which patients it is possible to achieve a Cum%VP &lt;= 40%. Methods and results Unselected, consecutive patients were implanted with a dual chamber pacemaker with a mean follow-up period of 76 days. The Cum%VP was calculated from device diagnostics between pre-hospital discharge (PHD) and the 1-month post implant visit. The median Cum%VP of 107 patients (age 67.2 +/- 14 years; 53% mate) who were programmed to MVP was 3.9%. The median Cum%VP was 1.4% in patients with sinus node disease (SND) and 28.8% in patients with AV block (AVB). Cum%VP &lt;= 40% was observed in 72% of all. patients, in 50% of AVB patients, and in 86% of SND patients. Conclusion The MVP mode is capable of achieving a tow percent of ventricular pacing in a standard pacemaker population with SND and AVB. In addition, 72% of patients in MVP mode demonstrated Cum%VP &lt;= 40%.}},
  author       = {{Milasinovic, Goran and Tscheliessnigg, Karlheinz and Boehmer, Anthonie and Vancura, Vladimir and Schuchert, Andreas and Brandt, Johan and Wiggenhorn, Christopher and Hofman, Maaike and Sperze, Johannes}},
  issn         = {{1532-2092}},
  keywords     = {{atrioventricular block; ventricular pacing; managed ventricular pacing; sinus node disease; pacing algorithms}},
  language     = {{eng}},
  number       = {{2}},
  pages        = {{151--155}},
  publisher    = {{Oxford University Press}},
  series       = {{Europace}},
  title        = {{Percent ventricular pacing with managed ventricular pacing mode in standard pacemaker population}},
  url          = {{http://dx.doi.org/10.1093/europace/eum288}},
  doi          = {{10.1093/europace/eum288}},
  volume       = {{10}},
  year         = {{2008}},
}