Delayed reactions to reusable protective gloves.

Pontén, Ann LU and Dubnika Hauksson, Inese LU (2009) In Contact Dermatitis 60(4). p.50-227
Abstract
The materials in plastic protective gloves are thought to cause less contact allergy than rubber gloves. Our aim was to estimate the frequency of delayed reactions to different types of reusable protective gloves among dermatitis patients. 2 x 2 cm pieces of polyvinyl chloride (PVC) gloves, nitrile gloves, and natural rubber latex (NRL) gloves were tested as is in consecutive dermatitis patients tested with the baseline series. Among 658 patients, 6 patients reacted to PVC gloves and 6 patients to the NRL gloves. None reacted to both these types of gloves. Five of six patients with reactions to rubber gloves reacted to thiuram mix in the baseline series. Delayed reactions to reusable PVC gloves may be as common as to reusable NRL gloves.... (More)
The materials in plastic protective gloves are thought to cause less contact allergy than rubber gloves. Our aim was to estimate the frequency of delayed reactions to different types of reusable protective gloves among dermatitis patients. 2 x 2 cm pieces of polyvinyl chloride (PVC) gloves, nitrile gloves, and natural rubber latex (NRL) gloves were tested as is in consecutive dermatitis patients tested with the baseline series. Among 658 patients, 6 patients reacted to PVC gloves and 6 patients to the NRL gloves. None reacted to both these types of gloves. Five of six patients with reactions to rubber gloves reacted to thiuram mix in the baseline series. Delayed reactions to reusable PVC gloves may be as common as to reusable NRL gloves. In contrast to most reactions to the NRL glove, the reactions to the PVC glove had no obvious association with reactions to any allergen(s) in the baseline series. (Less)
Please use this url to cite or link to this publication:
author
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Contact Dermatitis
volume
60
issue
4
pages
50 - 227
publisher
Federation of European Neuroscience Societies and Blackwell Publishing Ltd
external identifiers
  • wos:000264609700011
  • pmid:19338595
  • scopus:63349104036
ISSN
0105-1873
DOI
10.1111/j.1600-0536.2009.01510.x
language
English
LU publication?
yes
id
b9b225fa-9657-4237-9ef8-07198b5e6903 (old id 1392514)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/19338595?dopt=Abstract
date added to LUP
2009-05-04 15:42:08
date last changed
2017-01-01 07:31:52
@article{b9b225fa-9657-4237-9ef8-07198b5e6903,
  abstract     = {The materials in plastic protective gloves are thought to cause less contact allergy than rubber gloves. Our aim was to estimate the frequency of delayed reactions to different types of reusable protective gloves among dermatitis patients. 2 x 2 cm pieces of polyvinyl chloride (PVC) gloves, nitrile gloves, and natural rubber latex (NRL) gloves were tested as is in consecutive dermatitis patients tested with the baseline series. Among 658 patients, 6 patients reacted to PVC gloves and 6 patients to the NRL gloves. None reacted to both these types of gloves. Five of six patients with reactions to rubber gloves reacted to thiuram mix in the baseline series. Delayed reactions to reusable PVC gloves may be as common as to reusable NRL gloves. In contrast to most reactions to the NRL glove, the reactions to the PVC glove had no obvious association with reactions to any allergen(s) in the baseline series.},
  author       = {Pontén, Ann and Dubnika Hauksson, Inese},
  issn         = {0105-1873},
  language     = {eng},
  number       = {4},
  pages        = {50--227},
  publisher    = {Federation of European Neuroscience Societies and Blackwell Publishing Ltd},
  series       = {Contact Dermatitis},
  title        = {Delayed reactions to reusable protective gloves.},
  url          = {http://dx.doi.org/10.1111/j.1600-0536.2009.01510.x},
  volume       = {60},
  year         = {2009},
}