Disposable Electrodes for Capacitive Immunosensor
(2009) In Electroanalysis 21(9). p.1066-1074- Abstract
- Disposable electrodes were fabricated by coating chromium (5 nm) and gold (200 nm) on glass strips (5.0 mm x 25.4 mm) and used in a label-free immunosensor. Human Serum albumin (HSA) and its antigen (anti-HSA) were used as a model system. Electropolymerization of o-phenylenediamine was used for the immobilization of anti-HSA by covalent binding. A linear relationship was obtained in the range from 1.0 x 10-(14) to 1.0 x 10-(19) M with a limit of detection of 8.0 x 10(-15) M. Each modified electrode can be reused up to 30 times. The developed system was applied for human serum samples and compared to Albumin BCG method.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1425688
- author
- Teeparuksapun, Kosin ; Kanatharana, Proespichaya ; Limbut, Warakorn ; Thammakhet, Chongdee ; Asawatreratanakul, Punnee ; Mattiasson, Bo LU ; Wongkittisuksa, Booncharoen ; Limsakul, Chusak and Thavarungkul, Panote
- organization
- publishing date
- 2009
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Capacitive immunosensor, o-Phenylenediamine, Disposable electrode, Thermal evaporation, Human serum albumin
- in
- Electroanalysis
- volume
- 21
- issue
- 9
- pages
- 1066 - 1074
- publisher
- John Wiley & Sons Inc.
- external identifiers
-
- wos:000266153000009
- scopus:66649135028
- ISSN
- 1040-0397
- DOI
- 10.1002/elan.200804517
- language
- English
- LU publication?
- yes
- id
- 43c1f966-6df2-431d-9b4f-0ad8b2c7e023 (old id 1425688)
- date added to LUP
- 2016-04-01 14:34:49
- date last changed
- 2022-03-22 00:45:40
@article{43c1f966-6df2-431d-9b4f-0ad8b2c7e023, abstract = {{Disposable electrodes were fabricated by coating chromium (5 nm) and gold (200 nm) on glass strips (5.0 mm x 25.4 mm) and used in a label-free immunosensor. Human Serum albumin (HSA) and its antigen (anti-HSA) were used as a model system. Electropolymerization of o-phenylenediamine was used for the immobilization of anti-HSA by covalent binding. A linear relationship was obtained in the range from 1.0 x 10-(14) to 1.0 x 10-(19) M with a limit of detection of 8.0 x 10(-15) M. Each modified electrode can be reused up to 30 times. The developed system was applied for human serum samples and compared to Albumin BCG method.}}, author = {{Teeparuksapun, Kosin and Kanatharana, Proespichaya and Limbut, Warakorn and Thammakhet, Chongdee and Asawatreratanakul, Punnee and Mattiasson, Bo and Wongkittisuksa, Booncharoen and Limsakul, Chusak and Thavarungkul, Panote}}, issn = {{1040-0397}}, keywords = {{Capacitive immunosensor; o-Phenylenediamine; Disposable electrode; Thermal evaporation; Human serum albumin}}, language = {{eng}}, number = {{9}}, pages = {{1066--1074}}, publisher = {{John Wiley & Sons Inc.}}, series = {{Electroanalysis}}, title = {{Disposable Electrodes for Capacitive Immunosensor}}, url = {{http://dx.doi.org/10.1002/elan.200804517}}, doi = {{10.1002/elan.200804517}}, volume = {{21}}, year = {{2009}}, }