Amperometric Biosensor For Ethanol Based On A Phenothiazine Derivative Modified Carbon Paste Electrode
(2008) In Studia Universitatis Babes-Bolyai, Chemia 53(1). p.55-62- Abstract
- A new amperometric biosensor for ethanol, based on carbon paste electrode modified with alcohol dehydrogenase (ADH), polyethylenimine (PEI) and using a phenothiazine derivative (DDDP; 16H,18H-dibenzo[c,1]7,9-dithia-16,18-diazapentacene) as redox mediator for NADH recycling, was developed. The biosensor response is the result of mediated oxidation of NADH, generated in the enzymatic reaction between ADH and ethanol (in the presence of NAD(+)). The biosensor sensitivity (calculated as the ratio I-max/K-M(app)) was 0.035 mA M-1 and the detection limit was 0.26 mM, while the linear response range was from 0.1 to 20 mM ethanol.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1428191
- author
- Gligor, Delia ; Csöregi, Elisabeth LU and Popescu, Ionel Catalin
- organization
- publishing date
- 2008
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- phenothiazine derivative, adenine dinucleotide, nicotinamide, ethanol, amperometric biosensors, alcohol dehydrogenase, polyethyleneimine, modified carbon paste electrodes
- in
- Studia Universitatis Babes-Bolyai, Chemia
- volume
- 53
- issue
- 1
- pages
- 55 - 62
- publisher
- Universitatea Babes-Bolyai
- external identifiers
-
- wos:000266403700008
- ISSN
- 2065-9520
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004)
- id
- 0d8ef4f3-c39c-43ae-8b08-afd57cc56e65 (old id 1428191)
- date added to LUP
- 2016-04-01 12:11:08
- date last changed
- 2018-11-21 20:04:44
@article{0d8ef4f3-c39c-43ae-8b08-afd57cc56e65, abstract = {{A new amperometric biosensor for ethanol, based on carbon paste electrode modified with alcohol dehydrogenase (ADH), polyethylenimine (PEI) and using a phenothiazine derivative (DDDP; 16H,18H-dibenzo[c,1]7,9-dithia-16,18-diazapentacene) as redox mediator for NADH recycling, was developed. The biosensor response is the result of mediated oxidation of NADH, generated in the enzymatic reaction between ADH and ethanol (in the presence of NAD(+)). The biosensor sensitivity (calculated as the ratio I-max/K-M(app)) was 0.035 mA M-1 and the detection limit was 0.26 mM, while the linear response range was from 0.1 to 20 mM ethanol.}}, author = {{Gligor, Delia and Csöregi, Elisabeth and Popescu, Ionel Catalin}}, issn = {{2065-9520}}, keywords = {{phenothiazine derivative; adenine dinucleotide; nicotinamide; ethanol; amperometric biosensors; alcohol dehydrogenase; polyethyleneimine; modified carbon paste electrodes}}, language = {{eng}}, number = {{1}}, pages = {{55--62}}, publisher = {{Universitatea Babes-Bolyai}}, series = {{Studia Universitatis Babes-Bolyai, Chemia}}, title = {{Amperometric Biosensor For Ethanol Based On A Phenothiazine Derivative Modified Carbon Paste Electrode}}, volume = {{53}}, year = {{2008}}, }