Cemented tibial component fixation performs better than cementless fixation: a randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years.
(2005) In Acta Orthopaedica 76(3). p.362-369
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/143719
- author
- Carlsson, Åke LU ; Björkman, Anders LU ; Besjakov, Jack LU and Önsten, Ingemar LU
- organization
- publishing date
- 2005
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Knee: surgery, Porosity, Prosthesis Design, Prosthesis Failure, Reoperation, Female, Humans, Knee Prosthesis, Male, Osteoarthritis, Durapatite, Comparative Study, Biocompatible, Tibia: radiography, Tibia: surgery, Treatment Outcome, Knee, Bone Cements, Coated Materials, Replacement, Aged, Arthroplasty
- in
- Acta Orthopaedica
- volume
- 76
- issue
- 3
- pages
- 362 - 369
- publisher
- Taylor & Francis
- external identifiers
-
- wos:000231005300013
- pmid:16156464
- scopus:22844436086
- ISSN
- 1745-3682
- DOI
- 10.1080/00016470510030832
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Orthopaedics (013242900), Reconstructive Surgery (013240300), Medical Radiology Unit (013241410)
- id
- 0a7d9f10-d858-49c3-bc06-58e2c1c6ce7c (old id 143719)
- alternative location
- http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&list_uids=16156464&dopt=Abstract
- date added to LUP
- 2016-04-01 16:44:52
- date last changed
- 2022-05-08 20:20:03
@article{0a7d9f10-d858-49c3-bc06-58e2c1c6ce7c, author = {{Carlsson, Åke and Björkman, Anders and Besjakov, Jack and Önsten, Ingemar}}, issn = {{1745-3682}}, keywords = {{Knee: surgery; Porosity; Prosthesis Design; Prosthesis Failure; Reoperation; Female; Humans; Knee Prosthesis; Male; Osteoarthritis; Durapatite; Comparative Study; Biocompatible; Tibia: radiography; Tibia: surgery; Treatment Outcome; Knee; Bone Cements; Coated Materials; Replacement; Aged; Arthroplasty}}, language = {{eng}}, number = {{3}}, pages = {{362--369}}, publisher = {{Taylor & Francis}}, series = {{Acta Orthopaedica}}, title = {{Cemented tibial component fixation performs better than cementless fixation: a randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years.}}, url = {{http://dx.doi.org/10.1080/00016470510030832}}, doi = {{10.1080/00016470510030832}}, volume = {{76}}, year = {{2005}}, }