In an analytical-method comparison study of clinical samples, the Abbott RealTime CT new formulation assay (m2000 real-time PCR), consisting of a duplex PCR targeting different parts of the cryptic plasmid in Chlamydia trachomatis, was compared both with version 2 of the Roche Cobas TaqMan CT assay, comprising a duplex PCR for a target in the cryptic plasmid and the omp1 gene, and with the Gen-Probe Aptima Combo 2 assay (AC2) targeting the C. trachomatis 23S rRNA molecule. First-catch urine samples from Sweden were tested in Malmo, Sweden, for C. trachomatis with the m2000 real-time PCR assay and with an in-house PCR for the new variant C. trachomatis strain with a deletion in the cryptic plasmid. Aliquots of the urine samples were sent to... (More)
In an analytical-method comparison study of clinical samples, the Abbott RealTime CT new formulation assay (m2000 real-time PCR), consisting of a duplex PCR targeting different parts of the cryptic plasmid in Chlamydia trachomatis, was compared both with version 2 of the Roche Cobas TaqMan CT assay, comprising a duplex PCR for a target in the cryptic plasmid and the omp1 gene, and with the Gen-Probe Aptima Combo 2 assay (AC2) targeting the C. trachomatis 23S rRNA molecule. First-catch urine samples from Sweden were tested in Malmo, Sweden, for C. trachomatis with the m2000 real-time PCR assay and with an in-house PCR for the new variant C. trachomatis strain with a deletion in the cryptic plasmid. Aliquots of the urine samples were sent to Aarhus, Denmark, where they were further examined with the TaqMan CT and AC2 assays. A positive prevalence of 9.1% (148/1,632 urine samples examined) was detected according to the combined reference standard. The sensitivities and specificities of the three assays were as follows: for the Abbott m2000 assay, 95.3% (141/148) and 99.9% (1,483/1,485), respectively; for the Roche TaqMan assay, 82.4% (122/148) and 100.0% (1,485/1,485); and for the Gen-Probe AC2 assay, 99.3% (147/148) and 99.9% (1,484/1,485). The plasmid mutant strain was detected in 24% (36/148) of the C. trachomatis-positive samples. There is a difference in sensitivity between the new formulations of the Abbott and the Roche assays, but both assays detected the wild-type and new variant C. trachomatis strains equally well. (Less)
Please use this url to cite or link to this publication:
author
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Clinical Microbiology
volume
48
issue
2
pages
440 - 443
publisher
American Society for Microbiology
external identifiers
  • wos:000274151700013
  • scopus:75649118561
ISSN
1098-660X
DOI
10.1128/JCM.01446-09
language
English
LU publication?
yes
id
f545e9dc-8534-49e7-b32b-eb7c4f94fdb2 (old id 1570689)
date added to LUP
2010-03-17 08:27:47
date last changed
2018-05-29 12:07:25
@article{f545e9dc-8534-49e7-b32b-eb7c4f94fdb2,
  abstract     = {In an analytical-method comparison study of clinical samples, the Abbott RealTime CT new formulation assay (m2000 real-time PCR), consisting of a duplex PCR targeting different parts of the cryptic plasmid in Chlamydia trachomatis, was compared both with version 2 of the Roche Cobas TaqMan CT assay, comprising a duplex PCR for a target in the cryptic plasmid and the omp1 gene, and with the Gen-Probe Aptima Combo 2 assay (AC2) targeting the C. trachomatis 23S rRNA molecule. First-catch urine samples from Sweden were tested in Malmo, Sweden, for C. trachomatis with the m2000 real-time PCR assay and with an in-house PCR for the new variant C. trachomatis strain with a deletion in the cryptic plasmid. Aliquots of the urine samples were sent to Aarhus, Denmark, where they were further examined with the TaqMan CT and AC2 assays. A positive prevalence of 9.1% (148/1,632 urine samples examined) was detected according to the combined reference standard. The sensitivities and specificities of the three assays were as follows: for the Abbott m2000 assay, 95.3% (141/148) and 99.9% (1,483/1,485), respectively; for the Roche TaqMan assay, 82.4% (122/148) and 100.0% (1,485/1,485); and for the Gen-Probe AC2 assay, 99.3% (147/148) and 99.9% (1,484/1,485). The plasmid mutant strain was detected in 24% (36/148) of the C. trachomatis-positive samples. There is a difference in sensitivity between the new formulations of the Abbott and the Roche assays, but both assays detected the wild-type and new variant C. trachomatis strains equally well.},
  author       = {Moller, Jens Kjolseth and Pedersen, Lisbeth Norum and Persson, Kenneth},
  issn         = {1098-660X},
  language     = {eng},
  number       = {2},
  pages        = {440--443},
  publisher    = {American Society for Microbiology},
  series       = {Journal of Clinical Microbiology},
  title        = {Comparison of the Abbott RealTime CT New Formulation Assay with Two Other Commercial Assays for Detection of Wild-Type and New Variant Strains of Chlamydia trachomatis},
  url          = {http://dx.doi.org/10.1128/JCM.01446-09},
  volume       = {48},
  year         = {2010},
}