Robotics versus laparoscopy - an experimental study of the transfer effect in maiden users.
(2010) In Annals of Surgical Innovation and Research 4. p.3-3- Abstract
- ABSTRACT: BACKGROUND: Robot-assisted laparoscopy (RL) is used in a wide range of operative interventions, but the advantage of this technique over conventional laparoscopy (CL) remains unclear. Studies comparing RL and CL are scarce. The present study was performed to test the hypothesis that maiden users master surgical tasks quicker with the robot-assisted laparoscopy technique than with the conventional laparoscopy technique. METHODS: 20 subjects, with no prior surgical experience, performed three different surgical tasks in a standardized experimental setting, repeated four times with each of the RL and CL techniques. Speed and accuracy were measured. A cross-over technique was used to eliminate gender bias and the experience gained by... (More)
- ABSTRACT: BACKGROUND: Robot-assisted laparoscopy (RL) is used in a wide range of operative interventions, but the advantage of this technique over conventional laparoscopy (CL) remains unclear. Studies comparing RL and CL are scarce. The present study was performed to test the hypothesis that maiden users master surgical tasks quicker with the robot-assisted laparoscopy technique than with the conventional laparoscopy technique. METHODS: 20 subjects, with no prior surgical experience, performed three different surgical tasks in a standardized experimental setting, repeated four times with each of the RL and CL techniques. Speed and accuracy were measured. A cross-over technique was used to eliminate gender bias and the experience gained by carrying out the first part of the study. RESULTS: The task "tie a knot" was performed faster with the RL technique than with CL. Furthermore, shorter operating times were observed when changing from CL to RL. There were no time differences for the tasks of grabbing the needle and continuous suturing between the two operating techniques. Gender did not influence the results. CONCLUSION: The more advanced task of tying a knot was performed faster using the RL technique than with CL. Simpler surgical interventions were performed equally fast with either technique. Technical skills acquired during the use of CL were transferred to the RL technique. The lack of tactile feedback in RL seemed to matter. There were no differences between males and females. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1595556
- author
- Anderberg, Magnus
LU
; Larsson, Johan ; Clementson Kockum, Christina LU and Arnbjörnsson, Einar LU
- organization
- publishing date
- 2010
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Annals of Surgical Innovation and Research
- volume
- 4
- pages
- 3 - 3
- publisher
- BioMed Central (BMC)
- external identifiers
-
- pmid:20370924
- scopus:77950547245
- pmid:20370924
- ISSN
- 1750-1164
- DOI
- 10.1186/1750-1164-4-3
- language
- English
- LU publication?
- yes
- id
- 50545380-980d-40b0-ac4a-5870916ff1e7 (old id 1595556)
- alternative location
- http://www.ncbi.nlm.nih.gov/pubmed/20370924?dopt=Abstract
- date added to LUP
- 2016-04-04 09:36:33
- date last changed
- 2022-03-23 06:25:04
@article{50545380-980d-40b0-ac4a-5870916ff1e7, abstract = {{ABSTRACT: BACKGROUND: Robot-assisted laparoscopy (RL) is used in a wide range of operative interventions, but the advantage of this technique over conventional laparoscopy (CL) remains unclear. Studies comparing RL and CL are scarce. The present study was performed to test the hypothesis that maiden users master surgical tasks quicker with the robot-assisted laparoscopy technique than with the conventional laparoscopy technique. METHODS: 20 subjects, with no prior surgical experience, performed three different surgical tasks in a standardized experimental setting, repeated four times with each of the RL and CL techniques. Speed and accuracy were measured. A cross-over technique was used to eliminate gender bias and the experience gained by carrying out the first part of the study. RESULTS: The task "tie a knot" was performed faster with the RL technique than with CL. Furthermore, shorter operating times were observed when changing from CL to RL. There were no time differences for the tasks of grabbing the needle and continuous suturing between the two operating techniques. Gender did not influence the results. CONCLUSION: The more advanced task of tying a knot was performed faster using the RL technique than with CL. Simpler surgical interventions were performed equally fast with either technique. Technical skills acquired during the use of CL were transferred to the RL technique. The lack of tactile feedback in RL seemed to matter. There were no differences between males and females.}}, author = {{Anderberg, Magnus and Larsson, Johan and Clementson Kockum, Christina and Arnbjörnsson, Einar}}, issn = {{1750-1164}}, language = {{eng}}, pages = {{3--3}}, publisher = {{BioMed Central (BMC)}}, series = {{Annals of Surgical Innovation and Research}}, title = {{Robotics versus laparoscopy - an experimental study of the transfer effect in maiden users.}}, url = {{https://lup.lub.lu.se/search/files/5369708/1615890.pdf}}, doi = {{10.1186/1750-1164-4-3}}, volume = {{4}}, year = {{2010}}, }