Proximal placement of limb electrodes: a potential solution for acquiring standard electrocardiogram waveforms from monitoring electrode positions.

Pahlm, Olle LU and Wagner, Galen S (2008) In Journal of Electrocardiology 41. p.454-457
Abstract
There is currently a challenge to produce an electrocardiogram (ECG) recording of waveforms that are "standard" and also achieve the "noise immunity" required for continuous monitoring. The potential solutions that have been considered are to label each torso-recorded ECG as "nonstandard, torso-recorded," designate torso placement as "standard," or to reconstruct the "equivalent distally recorded ECG." The purpose of the present study was to validate an alternative "Lund system" of proximal limb electrode sites as a clinically feasible solution to this challenge. Data were collected from 75 patients referred for exercise testing at the Lund University Hospital. The Lund system produced Q wave dimensions and frontal plane QRS axis... (More)
There is currently a challenge to produce an electrocardiogram (ECG) recording of waveforms that are "standard" and also achieve the "noise immunity" required for continuous monitoring. The potential solutions that have been considered are to label each torso-recorded ECG as "nonstandard, torso-recorded," designate torso placement as "standard," or to reconstruct the "equivalent distally recorded ECG." The purpose of the present study was to validate an alternative "Lund system" of proximal limb electrode sites as a clinically feasible solution to this challenge. Data were collected from 75 patients referred for exercise testing at the Lund University Hospital. The Lund system produced Q wave dimensions and frontal plane QRS axis measurements that were in much better agreement with the standard ECG than those variables recorded with the Mason-Likar torso limb electrode method. Indeed, the Lund system replicated distal waveforms at a clinically acceptable level. Studies of larger patient cohorts including patients with various cardiac pathologies and studies of the noise immunity attained should be performed, and the acceptability by health care professionals should be determined. (Less)
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Electrocardiology
volume
41
pages
454 - 457
publisher
Elsevier
external identifiers
  • wos:000260917400002
  • pmid:18805543
  • scopus:55749114548
  • pmid:18805543
ISSN
1532-8430
DOI
10.1016/j.jelectrocard.2008.06.019
language
English
LU publication?
yes
id
1662287b-036e-4de4-b938-2043b45ff291 (old id 1242824)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/18805543?dopt=Abstract
date added to LUP
2016-04-04 07:35:52
date last changed
2022-02-20 20:35:26
@article{1662287b-036e-4de4-b938-2043b45ff291,
  abstract     = {{There is currently a challenge to produce an electrocardiogram (ECG) recording of waveforms that are "standard" and also achieve the "noise immunity" required for continuous monitoring. The potential solutions that have been considered are to label each torso-recorded ECG as "nonstandard, torso-recorded," designate torso placement as "standard," or to reconstruct the "equivalent distally recorded ECG." The purpose of the present study was to validate an alternative "Lund system" of proximal limb electrode sites as a clinically feasible solution to this challenge. Data were collected from 75 patients referred for exercise testing at the Lund University Hospital. The Lund system produced Q wave dimensions and frontal plane QRS axis measurements that were in much better agreement with the standard ECG than those variables recorded with the Mason-Likar torso limb electrode method. Indeed, the Lund system replicated distal waveforms at a clinically acceptable level. Studies of larger patient cohorts including patients with various cardiac pathologies and studies of the noise immunity attained should be performed, and the acceptability by health care professionals should be determined.}},
  author       = {{Pahlm, Olle and Wagner, Galen S}},
  issn         = {{1532-8430}},
  language     = {{eng}},
  pages        = {{454--457}},
  publisher    = {{Elsevier}},
  series       = {{Journal of Electrocardiology}},
  title        = {{Proximal placement of limb electrodes: a potential solution for acquiring standard electrocardiogram waveforms from monitoring electrode positions.}},
  url          = {{http://dx.doi.org/10.1016/j.jelectrocard.2008.06.019}},
  doi          = {{10.1016/j.jelectrocard.2008.06.019}},
  volume       = {{41}},
  year         = {{2008}},
}